CHLORIDE-ENVIRONMENT-SENSOR-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
2
Rows
2
Columns
36

sensorTable

table mandatory
.0.1364.10.2 · 1 row entry · 33 columns
A list of sensor table entries.
sensorEntry entry .0.1364.10.2.1
Indexes
No indexes recorded
Column Syntax OID
name mandatory
A string identifying the sensor.
OctetStringr/w .0.1364.10.2.1.1
status mandatory
Overall status of the sensor determined by the most severe sensor alarm present.
Enumeration .0.1364.10.2.1.2
address mandatory
The Blue Bus address of the environment sensor.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.0.1364.10.2.1.3
temperature mandatory
Current temperature reading in celsius.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.0.1364.10.2.1.4
tempStatus mandatory
Temperature status determined by tempLoSeverity and tempHiSeverity objects.
Enumeration .0.1364.10.2.1.5
tempHiSeverity mandatory
Severity level when temperature is greater than or equal to tempHiThreshold.
Enumerationr/w .0.1364.10.2.1.6
tempLoSeverity mandatory
Severity level when temperature is less than or equal to tempLoThreshold.
Enumerationr/w .0.1364.10.2.1.7
tempHiThreshold mandatory
When the the temperature is greater than or equal to this value, the sensorHiTemperature alarm is generated.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.0.1364.10.2.1.8
tempLoThreshold mandatory
When the the temperature is less than or equal to this value, the sensorLoTemperature alarm is generated.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.0.1364.10.2.1.9
humidity mandatory
Current relative humidity reading in percent.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.0.1364.10.2.1.10
humidityStatus mandatory
Relative humidity status determined by humidityHiSeverity and humidityLoSeverity objects.
Enumeration .0.1364.10.2.1.11
humidityHiSeverity mandatory
Severity level when relative humidity is greater than or equal to humidityHiThreshold.
Enumerationr/w .0.1364.10.2.1.12
humidityLoSeverity mandatory
Severity level when relative humidity is less than or equal to humidityLoThreshold.
Enumerationr/w .0.1364.10.2.1.13
humidityHiThreshold mandatory
When the the relative humidity is greater than or equal to this value, the sensorHiRelativeHumidity alarm is generated.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.0.1364.10.2.1.14
humidityLoThreshold mandatory
When the relative humidity is less than or equal to this value, the sensorLoRelativeHumidity alarm is generated.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.0.1364.10.2.1.15
inputName1 mandatory
A string identifying the device on input 1.
OctetStringr/w .0.1364.10.2.1.16
inputStatus1 mandatory
The status of the current state of input 1.
Enumeration .0.1364.10.2.1.17
inputNormalState1 mandatory
The normal state of input 1 ( open or closed ).
Enumerationr/w .0.1364.10.2.1.18
inputFaultSeverity1 mandatory
Severity level when input 1 is not in its normal state as defined by inputNormalState1.
Enumerationr/w .0.1364.10.2.1.19
inputUrl1 mandatory
An optional string identifying the URL associated with the device on input 1.
OctetStringr/w .0.1364.10.2.1.20
inputName2 mandatory
A string identifying the device on input 2.
OctetStringr/w .0.1364.10.2.1.21
inputStatus2 mandatory
The status of the current state of input 2.
Enumeration .0.1364.10.2.1.22
inputNormalState2 mandatory
The normal state of input 2 ( open or closed ).
Enumerationr/w .0.1364.10.2.1.23
inputFaultSeverity2 mandatory
Severity level when input 2 is not in its normal state as defined by inputNormalState2.
Enumerationr/w .0.1364.10.2.1.24
inputUrl2 mandatory
An optional string identifying the URL associated with the device on input 2.
OctetStringr/w .0.1364.10.2.1.25
inputName3 mandatory
A string identifying the device on input 3.
OctetStringr/w .0.1364.10.2.1.26
inputStatus3 mandatory
The status of the current state of input 3.
Enumeration .0.1364.10.2.1.27
inputNormalState3 mandatory
The normal state of input 3 ( open or closed ).
Enumerationr/w .0.1364.10.2.1.28
inputFaultSeverity3 mandatory
Severity level when input 3 is not in its normal state as defined by inputNormalState3.
Enumerationr/w .0.1364.10.2.1.29
inputUrl3 mandatory
An optional string identifying the URL associated with the device on input 3.
OctetStringr/w .0.1364.10.2.1.30
outputName mandatory
A string identifying the device attached to the output relay.
OctetStringr/w .0.1364.10.2.1.31
outputState mandatory
The state of the output relay ( on = energized, off = de-energized ).
Enumerationr/w .0.1364.10.2.1.32
outputUrl mandatory
An optional string identifying the URL associated with the device attached to the output relay.
OctetStringr/w .0.1364.10.2.1.33

alarmTable

table mandatory
.0.1364.10.3.2 · 1 row entry · 3 columns
A list of alarm entries.
alarmEntry entry .0.1364.10.3.2.1
Indexes
No indexes recorded
Column Syntax OID
alarmAddress mandatory
The Blue Bus address of the sensor which generated the alarm.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.0.1364.10.3.2.1.1
alarmDescr mandatory
The OID of the alarm generated.
.0.1364.10.3.2.1.2
alarmTime mandatory
The value of sysUpTime when the alarm condition was detected.
.0.1364.10.3.2.1.3