Baytech-MIB-401-4 Table View
Table-centric layout grouping table, row, and column objects.
Tables
11
Rows
11
Columns
116
.1.3.6.1.4.1.4779.1.2.8.4
·
1 row entry
·
2 columns
A list of managers to send traps to. The number of entries is given by the value of sBTANetworkConfigSNMPNumTrapReceivers. Maximum number of Trap Receivers is four.
Table of managers to send traps to.
Indexes
trapIndex
| Column | Syntax | OID |
|---|---|---|
|
trapIndex
mandatory
The index to a trap receiver entry.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.2.8.4.1.1 |
|
receiverAddress
mandatory
The IP address of the manager to send traps to.
|
RFC1155-SMIIpAddressr/w Textual Convention: RFC1155-SMIIpAddress OctetStringType Constraints: range: 4 |
.1.3.6.1.4.1.4779.1.2.8.4.1.2 |
.1.3.6.1.4.1.4779.1.3.5.2
·
1 row entry
·
24 columns
Allows for control of individual outlets and individual RPC modules.
The RPCs to control and get status on.
Indexes
sBTAModulesRPCIndex
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
sBTAModulesRPCIndex
mandatory
The index into the RPC table. Indexes for rpcs attached to ds74 modules are calculate with the following formula:
((module - 2) * 4) + port. For example module 3 port 1 = index 5. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.2.1.1 |
||||||||||||||
|
sBTAModulesRPCName
mandatory
The name (unit id) of the rpc.
|
RFC1213-MIBDisplayStringr/w Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.4779.1.3.5.2.1.2 |
||||||||||||||
|
sBTAModulesRPCFirmwareVersion
mandatory
The firware version of the rpc.
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.4779.1.3.5.2.1.3 |
||||||||||||||
|
sBTAModulesRPCCurrent
mandatory
The current reading for the power strip.
If current measurement is not installed this value will always read 0. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.2.1.4 |
||||||||||||||
|
sBTAModulesRPCMaxCurrent
mandatory
The maximum detected current reading for the power strip.
If current measurement is not installed this value will always read 0. Setting this value to 0 will clear the maximum current detected. |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.2.1.5 |
||||||||||||||
|
sBTAModulesRPCVoltage
mandatory
The voltage reading for the power strip.
If voltage measurement is not installed this value will always read 0. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.2.1.6 |
||||||||||||||
|
sBTAModulesRPCPower
mandatory
The power reading for the power strip.
If power measurement is not installed this value will always read 0. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.2.1.7 |
||||||||||||||
|
sBTAModulesRPCTemperature
mandatory
The temperature reading for the power strip. Readings are in degrees C.
If temperature measurement is not installed this value will always read 0. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.2.1.8 |
||||||||||||||
|
sBTAModulesRPCRebootTimeout
mandatory
The length of off time for automatic reboot sequences.
Currently a read-only value set to the fixed reboot timeout. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.2.1.9 |
||||||||||||||
|
sBTAModulesRPCAllOutletsCmd
mandatory
Turns all outlets on, off or reboot.
0 = off 1 = on 2 = reboot A get will return unknown (6). |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.4779.1.3.5.2.1.10 |
||||||||||||||
|
sBTAModulesRPCAllOutletsStatus
mandatory
Reports status of outlets in a comma deliminated string.
0 = off 1 = on 2 = reboot 3 = locked on 4 = locked off |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.4779.1.3.5.2.1.11 |
||||||||||||||
|
sBTAModulesRPCCurrentAlarmThreshold
mandatory
The current alarm threshold level *10. A value of 105 will set the level to 10.5.
|
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.2.1.12 |
||||||||||||||
|
sBTAModulesRPCOverVoltageThreshold
mandatory
The over voltage alarm threshold level *10. A value of 105 will set the level to 10.5.
|
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.2.1.13 |
||||||||||||||
|
sBTAModulesRPCUnderVoltageThreshold
mandatory
The under voltage alarm threshold level *10. A value of 105 will set the level to 10.5.
|
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.2.1.14 |
||||||||||||||
|
sBTAModulesRPCNumberOfOutlets
mandatory
Number of outlets for this RPC.
This will be the size of outlet table for this RPC index. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.2.1.15 |
||||||||||||||
|
sBTAModulesRPCCircuitBreaker
mandatory
Status of circuit breaker in power strip. 0=off 1=on.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.4779.1.3.5.2.1.16 |
||||||||||||||
|
sBTAModulesRPCOverTempThreshold
mandatory
The over temperature alarm threshold level *10. A value of 505 will set the level to 50.5.
|
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.2.1.17 |
||||||||||||||
|
sBTAModulesRPCUnitVA
mandatory
Total Volt-Amps for this RPC.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.2.1.18 |
||||||||||||||
|
sBTAModulesRPCNumberOfBreakers
mandatory
Number of breakers for this RPC.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.2.1.19 |
||||||||||||||
|
sBTAModulesRPCLowCurrentThreshold
mandatory
Low current threshold for this RPC.
|
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.2.1.20 |
||||||||||||||
|
sBTAModulesRPCVoltageSource
mandatory
Voltage source for this RPC.
|
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.2.1.21 |
||||||||||||||
|
sBTAModulesRPCSourceSwitchCount
mandatory
Count of Voltage Source Switches for this RPC.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.2.1.22 |
||||||||||||||
|
sBTAModulesRPCNumberOfSensors
mandatory
Number of environmental sensors for this RPC.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.2.1.23 |
||||||||||||||
|
sBTAModulesRPCType
mandatory
The type of RPC installed at the indexed location.
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.4779.1.3.5.2.1.24 |
.1.3.6.1.4.1.4779.1.3.5.3
·
1 row entry
·
4 columns
Allows for control of individual outlets. The number of entries is contained in the sBTAModulesRPCOutletTableSize OID.
The outlets to control and get status on.
Indexes
sBTAModulesRPCOutletModuleIndex sBTAModulesRPCOutletIndex
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
sBTAModulesRPCOutletModuleIndex
mandatory
The index to the outlet entry.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.3.1.1 |
||||||||||||||
|
sBTAModulesRPCOutletIndex
mandatory
The index to the outlet entry.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.3.1.2 |
||||||||||||||
|
sBTAModulesRPCOutletState
mandatory
Getting this variable will return the state of the outlet.
Valid return states are unknown, on, off, lockon, lockoff. 0 = off 1 = on 2 = reboot 3 = lockon (outlet is on and no changes are allowed) 4 = lockoff (outlet is… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.4779.1.3.5.3.1.3 |
||||||||||||||
|
sBTAModulesRPCOutletName
mandatory
The name of the outlet. Maximum size is 16 characters.
|
RFC1213-MIBDisplayStringr/w Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.4779.1.3.5.3.1.4 |
.1.3.6.1.4.1.4779.1.3.5.5
·
1 row entry
·
25 columns
Allows for control of individual outlets and individual RPC modules. The number of entries is contained in the sBTAModulesNumberOfRPCModules OID.
The RPCs to control and get status on.
Indexes
sRPCModuleIndex sRPCPortIndex
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
sRPCModuleIndex
mandatory
The module number index into the RPC table.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.5.1.1 |
||||||||||||||
|
sRPCPortIndex
mandatory
The port number index into the RPC table. In the case of ds30 modules this number is always 1.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.5.1.2 |
||||||||||||||
|
sRPCType
mandatory
Type of RPC at the module, port index.
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.4779.1.3.5.5.1.3 |
||||||||||||||
|
sRPCName
mandatory
The name (unit id) of the rpc module.
|
RFC1213-MIBDisplayStringr/w Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.4779.1.3.5.5.1.4 |
||||||||||||||
|
sRPCFirmwareVersion
mandatory
The firware version of the rpc module.
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.4779.1.3.5.5.1.5 |
||||||||||||||
|
sRPCCurrent
mandatory
The current reading for the power strip.
If current measurement is not installed this value will always read 0. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.5.1.6 |
||||||||||||||
|
sRPCMaxCurrent
mandatory
The maximum detected current reading for the power strip.
If current measurement is not installed this value will always read 0. Setting this value to 0 will clear the maximum current detected. |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.5.1.7 |
||||||||||||||
|
sRPCVoltage
mandatory
The voltage reading for the power strip.
If voltage measurement is not installed this value will always read 0. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.5.1.8 |
||||||||||||||
|
sRPCPower
mandatory
The power reading for the power strip.
If power measurement is not installed this value will always read 0. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.5.1.9 |
||||||||||||||
|
sRPCTemperature
mandatory
The temperature reading for the power strip. Readings are in degrees C.
If temperature measurement is not installed this value will always read 0. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.5.1.10 |
||||||||||||||
|
sRPCRebootTimeout
mandatory
The length of off time for automatic reboot sequences.
Currently a read-only value set to the fixed reboot timeout. |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.5.1.11 |
||||||||||||||
|
sRPCAllOutletsCmd
mandatory
Turns all outlets on, off or reboot.
0 = off 1 = on 2 = reboot 3 = lockon (will lock outlets to on state) 4 = lockoff (will lock outlets to off state) 5 = unlock (will unlock all outlets) A get will retur… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.4779.1.3.5.5.1.12 |
||||||||||||||
|
sRPCAllOutletsStatus
mandatory
Reports status of outlets in a comma deliminated string.
0 = off 1 = on 2 = reboot 3 = locked on 4 = locked off |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.4779.1.3.5.5.1.13 |
||||||||||||||
|
sRPCCurrentAlarmThreshold
mandatory
The current alarm threshold level *10. A value of 105 will set the level to 10.5.
|
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.5.1.14 |
||||||||||||||
|
sRPCOverVoltageThreshold
mandatory
The over voltage alarm threshold level *10. A value of 105 will set the level to 10.5.
|
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.5.1.15 |
||||||||||||||
|
sRPCUnderVoltageThreshold
mandatory
The under voltage alarm threshold level *10. A value of 105 will set the level to 10.5.
|
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.5.1.16 |
||||||||||||||
|
sRPCNumberOfOutlets
mandatory
Number of outlets for this RPC.
This will be the size of outlet table for this RPC index. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.5.1.17 |
||||||||||||||
|
sRPCCircuitBreaker
mandatory
Status of circuit breaker in power strip. 0=off 1=on.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.4779.1.3.5.5.1.18 |
||||||||||||||
|
sRPCOverTempThreshold
mandatory
The over temperature alarm threshold level *10. A value of 505 will set the level to 50.5.
|
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.5.1.19 |
||||||||||||||
|
sRPCUnitVA
mandatory
Number of outlets for this RPC.
This will be the size of outlet table for this RPC index. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.5.1.20 |
||||||||||||||
|
sRPCNumberOfBreakers
mandatory
Number of breakers for this RPC.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.5.1.21 |
||||||||||||||
|
sRPCLowCurrentThreshold
mandatory
Low current threshold for this RPC.
|
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.5.1.22 |
||||||||||||||
|
sRPCVoltageSource
mandatory
Voltage source for this RPC.
|
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.5.1.23 |
||||||||||||||
|
sRPCSourceSwitchCount
mandatory
Voltage source switch count for this RPC.
|
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.5.1.24 |
||||||||||||||
|
sRPCNumberOfSensors
mandatory
Number of sensors for this RPC.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.5.1.25 |
.1.3.6.1.4.1.4779.1.3.5.6
·
1 row entry
·
5 columns
Allows for control of individual outlets. The number of entries is contained in the sBTAModulesRPCOutletTableSize OID.
The outlets to control and get status on.
Indexes
sRPCOutletModuleIndex sRPCOutletPortIndex sRPCOutletIndex
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
sRPCOutletModuleIndex
mandatory
The module index to the outlet entry.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.6.1.1 |
||||||||||||||
|
sRPCOutletPortIndex
mandatory
The port index to the outlet entry. In the case of ds30s this number is always 1.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.6.1.2 |
||||||||||||||
|
sRPCOutletIndex
mandatory
The outlet index to the outlet entry.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.6.1.3 |
||||||||||||||
|
sRPCOutletState
mandatory
Getting this variable will return the state of the outlet.
Valid return states are unknown, on, off, lockon, lockoff. 0 = off 1 = on 2 = reboot 3 = lockon (outlet is on and no changes are allowed) 4 = lockoff (outlet is… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.4779.1.3.5.6.1.4 |
||||||||||||||
|
sRPCOutletName
mandatory
The name of the outlet. Maximum size is 16 characters.
|
RFC1213-MIBDisplayStringr/w Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.4779.1.3.5.6.1.5 |
.1.3.6.1.4.1.4779.1.3.5.8
·
1 row entry
·
5 columns
A list of total current for RPCs in each current group
Table of total current measurement by group
Indexes
groupCurrentIndex
| Column | Syntax | OID |
|---|---|---|
|
groupCurrentIndex
mandatory
The index to a group total current.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.8.1.1 |
|
groupCurrent
mandatory
Current total for all RPCs in group.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.8.1.2 |
|
rpcGroup
mandatory
A character string listing the RPCs, by port index, that will be
included in a measurement of total current. For each group, a sum will be periodically computed of currents of all listed RPCs, which will be compared to… |
RFC1213-MIBDisplayStringr/w Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.4779.1.3.5.8.1.3 |
|
warningThreshold
mandatory
The current level, in tenths of an amp, that will cause a Current
Level Warning trap to be sent if the total current for the associated group if exceeded. Conversely, a Current Level Warning Clear trap will be sent w… |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.8.1.4 |
|
emergencyThreshold
mandatory
The current level, in tenths of an amp, that will cause a Current
Level Emergency trap to be sent if the total current for the associated group if exceeded. Conversely, a Current Level Emergeny Clear trap will be sen… |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.8.1.5 |
.1.3.6.1.4.1.4779.1.3.5.9
·
1 row entry
·
9 columns
Allows monitoring of individual outlet strips on RPCs.
Status organization by breaker.
Indexes
sBTAModulesRPCBreakersModulesIndex sBTAModulesRPCBreakersBreakersIndex
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
sBTAModulesRPCBreakersModulesIndex
mandatory
The index into the RPC table.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.9.1.1 |
||||
|
sBTAModulesRPCBreakersBreakersIndex
mandatory
The index into the RPC breaker table.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.9.1.2 |
||||
|
sBTAModulesRPCBreakersCircuitBreaker
mandatory
Status of circuit breaker in power strip. 0=off 1=on.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.4779.1.3.5.9.1.3 |
||||
|
sBTAModulesRPCBreakersCurrent
mandatory
The detected current reading for the power strip.
If current measurement is not installed this value will always read 0. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.9.1.4 |
||||
|
sBTAModulesRPCBreakersMaxCurrent
mandatory
The maximum detected current reading for the power strip.
If current measurement is not installed this value will always read 0. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.9.1.5 |
||||
|
sBTAModulesRPCBreakersVoltage
mandatory
The voltage reading for the power strip.
If voltage measurement is not installed this value will always read 0. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.9.1.6 |
||||
|
sBTAModulesRPCBreakersPower
mandatory
The power reading for the power strip.
If voltage measurement is not installed this value will always read 0. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.9.1.7 |
||||
|
sBTAModulesRPCBreakersVA
mandatory
The volt-amps reading for the power strip.
If voltage measurement is not installed this value will always read 0. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.9.1.8 |
||||
|
sBTAModulesRPCBreakersCurrentAlarmThreshold
mandatory
The current alarm threshold level *10. A value of 105 will set the level to 10.5.
|
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.9.1.9 |
.1.3.6.1.4.1.4779.1.3.5.10
·
1 row entry
·
10 columns
Allows monitoring of individual outlet strips on RPCs.
Status organization by breaker.
Indexes
sRPCBreakersModIndex sRPCBreakersPortIndex sRPCBreakersBreakersIndex
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
sRPCBreakersModIndex
mandatory
The module index into the RPC breaker table.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.10.1.1 |
||||
|
sRPCBreakersPortIndex
mandatory
The port index into the RPC breaker table.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.10.1.2 |
||||
|
sRPCBreakersBreakersIndex
mandatory
The breaker index into the RPC breaker table.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.10.1.3 |
||||
|
sRPCBreakersCircuitBreaker
mandatory
Status of circuit breaker in power strip. 0=off 1=on.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.4779.1.3.5.10.1.4 |
||||
|
sRPCBreakersCurrent
mandatory
The detected current reading for the power strip.
If current measurement is not installed this value will always read 0. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.10.1.5 |
||||
|
sRPCBreakersMaxCurrent
mandatory
The maximum detected current reading for the power strip.
If current measurement is not installed this value will always read 0. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.10.1.6 |
||||
|
sRPCBreakersVoltage
mandatory
The voltage reading for the power strip.
If voltage measurement is not installed this value will always read 0. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.10.1.7 |
||||
|
sRPCBreakersPower
mandatory
The power reading for the power strip.
If voltage measurement is not installed this value will always read 0. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.10.1.8 |
||||
|
sRPCBreakersVA
mandatory
The volt-amps reading for the power strip.
If voltage measurement is not installed this value will always read 0. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.10.1.9 |
||||
|
sRPCBreakersCurrentAlarmThreshold
mandatory
The current alarm threshold level x10. A value of 105 will set the level to 10.5.
|
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.10.1.10 |
.1.3.6.1.4.1.4779.1.4.4
·
1 row entry
·
7 columns
A list of users and user information. The number of entries is contained in the sBTAControlNumOfLoggedUsers OID.
The users to get status on.
Indexes
sBTAControlUserIndex
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
sBTAControlUserIndex
mandatory
The index to the user entry.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.4.4.1.1 |
||||||||
|
sBTAControlUserName
mandatory
The username of the user.
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.4779.1.4.4.1.2 |
||||||||
|
sBTAControlUserAddress
mandatory
The IP address of the user.
|
RFC1155-SMIIpAddress Textual Convention: RFC1155-SMIIpAddress OctetStringType Constraints: range: 4 |
.1.3.6.1.4.1.4779.1.4.4.1.3 |
||||||||
|
sBTAControlUserConnection
mandatory
Type of connection.
If unknown, user is logging out or the connection is invalid. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.4779.1.4.4.1.4 |
||||||||
|
sBTAControlUserConnModule
mandatory
If the user is connected to a module, this value will
report the module number connected to. If the value is 0 the user is not connected to a module. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.4.4.1.5 |
||||||||
|
sBTAControlUserConnPort
mandatory
The port number with in a module that the user is connected to.
This usually only applies to connections to DS74 serial modules. Intelligent modules connections are always made on port 1. If value is 0 the user is not c… |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.4.4.1.6 |
||||||||
|
sBTAControlUserTerminateUser
mandatory
Settings this OID to anything but 0 will terminate (log out) the user.
A get of this OID will return 0. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.4779.1.4.4.1.7 |
.1.3.6.1.4.1.4779.1.6.1
·
1 row entry
·
12 columns
Allows monitoring of individual outlet strips on RPCs.
Status organization by sensor.
Indexes
sBTAModulesEnvironmentalModulesIndex sBTAModulesEnvironmentalSensorsIndex
| Column | Syntax | OID |
|---|---|---|
|
sBTAModulesEnvironmentalModulesIndex
mandatory
Module Index for Environemntal table
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.6.1.1.1 |
|
sBTAModulesEnvironmentalSensorsIndex
mandatory
Sensor Index for Environemntal table
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.6.1.1.2 |
|
sBTAModulesEnvironmentalType
mandatory
Environmental Object Type.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.6.1.1.3 |
|
sBTAModulesEnvironmentalName
mandatory
The name for the environmental object.
|
RFC1213-MIBDisplayStringr/w Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.4779.1.6.1.1.4 |
|
sBTAModulesEnvironmentalMeasurement
mandatory
The measurement or state for the object.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.6.1.1.5 |
|
sBTAModulesEnvironmentalHiThreshold
mandatory
Hi threshold for object.
|
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.6.1.1.6 |
|
sBTAModulesEnvironmentalLoThreshold
mandatory
Lo threshold for object.
|
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.6.1.1.7 |
|
sBTAModulesEnvironmentalMax
mandatory
Max value recorded for object since last reset.
|
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.6.1.1.8 |
|
sBTAModulesEnvironmentalMin
mandatory
Min value recorded for object since last reset.
|
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.6.1.1.9 |
|
sBTAModulesEnvironmentalHiThresholdEn
mandatory
Hi threshold enable for object.
|
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.6.1.1.10 |
|
sBTAModulesEnvironmentalLoThresholdEn
mandatory
Lo threshold enable for object.
|
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.6.1.1.11 |
|
sBTAModulesEnvironmentalStateTrapEn
mandatory
Trap enable for environmental sensors with contacts.
|
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.6.1.1.12 |
.1.3.6.1.4.1.4779.1.6.2
·
1 row entry
·
13 columns
Allows monitoring of individual outlet strips on RPCs.
Status organization by sensor.
Indexes
sBTAEnvironmentalModuleIndex sBTAEnvironmentalPortIndex sBTAEnvironmentalSensorsIndex
| Column | Syntax | OID |
|---|---|---|
|
sRPCEnvironmentalModuleIndex
mandatory
Module Index for Environemntal table
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.6.2.1.1 |
|
sRPCEnvironmentalPortIndex
mandatory
Port Index for Environemntal table
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.6.2.1.2 |
|
sRPCEnvironmentalSensorsIndex
mandatory
Sensor Index for Environemntal table
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.6.2.1.3 |
|
sRPCEnvironmentalType
mandatory
Environmental Object Type.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.6.2.1.4 |
|
sRPCEnvironmentalName
mandatory
The name for the environmental object.
|
RFC1213-MIBDisplayStringr/w Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.4779.1.6.2.1.5 |
|
sRPCEnvironmentalMeasurement
mandatory
The measurement or state for the object.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.6.2.1.6 |
|
sRPCEnvironmentalHiThreshold
mandatory
Hi threshold for object.
|
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.6.2.1.7 |
|
sRPCEnvironmentalLoThreshold
mandatory
Lo threshold for object.
|
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.6.2.1.8 |
|
sRPCEnvironmentalMax
mandatory
Max value recorded for object since last reset.
|
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.6.2.1.9 |
|
sRPCEnvironmentalMin
mandatory
Min value recorded for object since last reset.
|
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.6.2.1.10 |
|
sRPCEnvironmentalHiThresholdEn
mandatory
Hi threshold enable for object.
|
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.6.2.1.11 |
|
sRPCEnvironmentalLoThresholdEn
mandatory
Lo threshold enable for object.
|
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.6.2.1.12 |
|
sRPCEnvironmentalStateTrapEn
mandatory
Trap enable for environmental sensors with contacts.
|
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.6.2.1.13 |