Baytech-MIB-401-4 Table View

Table-centric layout grouping table, row, and column objects.

Tables
11
Rows
11
Columns
116
.1.3.6.1.4.1.4779.1.2.8.4 · 1 row entry · 2 columns
A list of managers to send traps to.  The number of
entries is given by the value of sBTANetworkConfigSNMPNumTrapReceivers.
Maximum number of Trap Receivers is four.
sBTANetworkConfigSNMPTrapReceiverEntry entry .1.3.6.1.4.1.4779.1.2.8.4.1
Table of managers to send traps to.
Indexes
trapIndex
Column Syntax OID
trapIndex mandatory
The index to a trap receiver entry.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.2.8.4.1.1
receiverAddress mandatory
The IP address of the manager to send traps to.
RFC1155-SMIIpAddressr/w
Textual Convention: RFC1155-SMIIpAddress OctetString
Type Constraints:
range: 4
.1.3.6.1.4.1.4779.1.2.8.4.1.2

sBTAModulesRPCTable

table mandatory
.1.3.6.1.4.1.4779.1.3.5.2 · 1 row entry · 24 columns
Allows for control of individual outlets and individual RPC modules.
sBTAModulesRPCEntry entry .1.3.6.1.4.1.4779.1.3.5.2.1
The RPCs to control and get status on.
Indexes
sBTAModulesRPCIndex
Column Syntax OID
sBTAModulesRPCIndex mandatory
The index into the RPC table. Indexes for rpcs attached to ds74 modules are calculate with the following formula:
((module - 2) * 4) + port. For example module 3 port 1 = index 5.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.3.5.2.1.1
sBTAModulesRPCName mandatory
The name (unit id) of the rpc.
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.4779.1.3.5.2.1.2
sBTAModulesRPCFirmwareVersion mandatory
The firware version of the rpc.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.4779.1.3.5.2.1.3
sBTAModulesRPCCurrent mandatory
The current reading for the power strip.
If current measurement is not installed this value will always read 0.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.3.5.2.1.4
sBTAModulesRPCMaxCurrent mandatory
The maximum detected current reading for the power strip.
If current measurement is not installed this value will always read 0.
Setting this value to 0 will clear the maximum current detected.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.3.5.2.1.5
sBTAModulesRPCVoltage mandatory
The voltage reading for the power strip.
If voltage measurement is not installed this value will always read 0.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.3.5.2.1.6
sBTAModulesRPCPower mandatory
The power reading for the power strip.
If power measurement is not installed this value will always read 0.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.3.5.2.1.7
sBTAModulesRPCTemperature mandatory
The temperature reading for the power strip. Readings are in degrees C.
If temperature measurement is not installed this value will always read 0.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.3.5.2.1.8
sBTAModulesRPCRebootTimeout mandatory
The length of off time for automatic reboot sequences.
Currently a read-only value set to the fixed reboot timeout.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.3.5.2.1.9
sBTAModulesRPCAllOutletsCmd mandatory
Turns all outlets on, off or reboot.
0 = off
1 = on
2 = reboot

A get will return unknown (6).
Enumerationr/w
Enumerated Values:
0off
1on
2reboot
3lockon
4lockoff
5unlock
6unknown
.1.3.6.1.4.1.4779.1.3.5.2.1.10
sBTAModulesRPCAllOutletsStatus mandatory
Reports status of outlets in a comma deliminated string.
0 = off
1 = on
2 = reboot
3 = locked on
4 = locked off
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.4779.1.3.5.2.1.11
sBTAModulesRPCCurrentAlarmThreshold mandatory
The current alarm threshold level *10. A value of 105 will set the level to 10.5.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.3.5.2.1.12
sBTAModulesRPCOverVoltageThreshold mandatory
The over voltage alarm threshold level *10. A value of 105 will set the level to 10.5.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.3.5.2.1.13
sBTAModulesRPCUnderVoltageThreshold mandatory
The under voltage alarm threshold level *10. A value of 105 will set the level to 10.5.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.3.5.2.1.14
sBTAModulesRPCNumberOfOutlets mandatory
Number of outlets for this RPC.
This will be the size of outlet table for this RPC index.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.3.5.2.1.15
sBTAModulesRPCCircuitBreaker mandatory
Status of circuit breaker in power strip. 0=off 1=on.
Enumeration
Enumerated Values:
0off
1on
.1.3.6.1.4.1.4779.1.3.5.2.1.16
sBTAModulesRPCOverTempThreshold mandatory
The over temperature alarm threshold level *10. A value of 505 will set the level to 50.5.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.3.5.2.1.17
sBTAModulesRPCUnitVA mandatory
Total Volt-Amps for this RPC.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.3.5.2.1.18
sBTAModulesRPCNumberOfBreakers mandatory
Number of breakers for this RPC.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.3.5.2.1.19
sBTAModulesRPCLowCurrentThreshold mandatory
Low current threshold for this RPC.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.3.5.2.1.20
sBTAModulesRPCVoltageSource mandatory
Voltage source for this RPC.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.3.5.2.1.21
sBTAModulesRPCSourceSwitchCount mandatory
Count of Voltage Source Switches for this RPC.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.3.5.2.1.22
sBTAModulesRPCNumberOfSensors mandatory
Number of environmental sensors for this RPC.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.3.5.2.1.23
sBTAModulesRPCType mandatory
The type of RPC installed at the indexed location.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.4779.1.3.5.2.1.24
.1.3.6.1.4.1.4779.1.3.5.3 · 1 row entry · 4 columns
Allows for control of individual outlets. The number of
entries is contained in the sBTAModulesRPCOutletTableSize OID.
sBTAModulesRPCOutletEntry entry .1.3.6.1.4.1.4779.1.3.5.3.1
The outlets to control and get status on.
Indexes
sBTAModulesRPCOutletModuleIndex sBTAModulesRPCOutletIndex
Column Syntax OID
sBTAModulesRPCOutletModuleIndex mandatory
The index to the outlet entry.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.3.5.3.1.1
sBTAModulesRPCOutletIndex mandatory
The index to the outlet entry.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.3.5.3.1.2
sBTAModulesRPCOutletState mandatory
Getting this variable will return the state of the outlet.
Valid return states are unknown, on, off, lockon, lockoff.
0 = off
1 = on
2 = reboot
3 = lockon (outlet is on and no changes are allowed)
4 = lockoff (outlet is…
Enumerationr/w
Enumerated Values:
0off
1on
2reboot
3lockon
4lockoff
5unlock
6unknown
.1.3.6.1.4.1.4779.1.3.5.3.1.3
sBTAModulesRPCOutletName mandatory
The name of the outlet. Maximum size is 16 characters.
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.4779.1.3.5.3.1.4
.1.3.6.1.4.1.4779.1.3.5.5 · 1 row entry · 25 columns
Allows for control of individual outlets and individual RPC modules. The number of
entries is contained in the sBTAModulesNumberOfRPCModules OID.
sBTAModulesRPCModPortEntry entry .1.3.6.1.4.1.4779.1.3.5.5.1
The RPCs to control and get status on.
Indexes
sRPCModuleIndex sRPCPortIndex
Column Syntax OID
sRPCModuleIndex mandatory
The module number index into the RPC table.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.3.5.5.1.1
sRPCPortIndex mandatory
The port number index into the RPC table. In the case of ds30 modules this number is always 1.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.3.5.5.1.2
sRPCType mandatory
Type of RPC at the module, port index.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.4779.1.3.5.5.1.3
sRPCName mandatory
The name (unit id) of the rpc module.
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.4779.1.3.5.5.1.4
sRPCFirmwareVersion mandatory
The firware version of the rpc module.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.4779.1.3.5.5.1.5
sRPCCurrent mandatory
The current reading for the power strip.
If current measurement is not installed this value will always read 0.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.3.5.5.1.6
sRPCMaxCurrent mandatory
The maximum detected current reading for the power strip.
If current measurement is not installed this value will always read 0.
Setting this value to 0 will clear the maximum current detected.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.3.5.5.1.7
sRPCVoltage mandatory
The voltage reading for the power strip.
If voltage measurement is not installed this value will always read 0.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.3.5.5.1.8
sRPCPower mandatory
The power reading for the power strip.
If power measurement is not installed this value will always read 0.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.3.5.5.1.9
sRPCTemperature mandatory
The temperature reading for the power strip. Readings are in degrees C.
If temperature measurement is not installed this value will always read 0.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.3.5.5.1.10
sRPCRebootTimeout mandatory
The length of off time for automatic reboot sequences.
Currently a read-only value set to the fixed reboot timeout.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.3.5.5.1.11
sRPCAllOutletsCmd mandatory
Turns all outlets on, off or reboot.
0 = off
1 = on
2 = reboot
3 = lockon (will lock outlets to on state)
4 = lockoff (will lock outlets to off state)
5 = unlock (will unlock all outlets)

A get will retur…
Enumerationr/w
Enumerated Values:
0off
1on
2reboot
3lockon
4lockoff
5unlock
6unknown
.1.3.6.1.4.1.4779.1.3.5.5.1.12
sRPCAllOutletsStatus mandatory
Reports status of outlets in a comma deliminated string.
0 = off
1 = on
2 = reboot
3 = locked on
4 = locked off
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.4779.1.3.5.5.1.13
sRPCCurrentAlarmThreshold mandatory
The current alarm threshold level *10. A value of 105 will set the level to 10.5.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.3.5.5.1.14
sRPCOverVoltageThreshold mandatory
The over voltage alarm threshold level *10. A value of 105 will set the level to 10.5.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.3.5.5.1.15
sRPCUnderVoltageThreshold mandatory
The under voltage alarm threshold level *10. A value of 105 will set the level to 10.5.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.3.5.5.1.16
sRPCNumberOfOutlets mandatory
Number of outlets for this RPC.
This will be the size of outlet table for this RPC index.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.3.5.5.1.17
sRPCCircuitBreaker mandatory
Status of circuit breaker in power strip. 0=off 1=on.
Enumeration
Enumerated Values:
0off
1on
.1.3.6.1.4.1.4779.1.3.5.5.1.18
sRPCOverTempThreshold mandatory
The over temperature alarm threshold level *10. A value of 505 will set the level to 50.5.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.3.5.5.1.19
sRPCUnitVA mandatory
Number of outlets for this RPC.
This will be the size of outlet table for this RPC index.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.3.5.5.1.20
sRPCNumberOfBreakers mandatory
Number of breakers for this RPC.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.3.5.5.1.21
sRPCLowCurrentThreshold mandatory
Low current threshold for this RPC.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.3.5.5.1.22
sRPCVoltageSource mandatory
Voltage source for this RPC.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.3.5.5.1.23
sRPCSourceSwitchCount mandatory
Voltage source switch count for this RPC.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.3.5.5.1.24
sRPCNumberOfSensors mandatory
Number of sensors for this RPC.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.3.5.5.1.25
.1.3.6.1.4.1.4779.1.3.5.6 · 1 row entry · 5 columns
Allows for control of individual outlets. The number of
entries is contained in the sBTAModulesRPCOutletTableSize OID.
sBTAModulesRPCModPortOutletEntry entry .1.3.6.1.4.1.4779.1.3.5.6.1
The outlets to control and get status on.
Indexes
sRPCOutletModuleIndex sRPCOutletPortIndex sRPCOutletIndex
Column Syntax OID
sRPCOutletModuleIndex mandatory
The module index to the outlet entry.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.3.5.6.1.1
sRPCOutletPortIndex mandatory
The port index to the outlet entry. In the case of ds30s this number is always 1.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.3.5.6.1.2
sRPCOutletIndex mandatory
The outlet index to the outlet entry.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.3.5.6.1.3
sRPCOutletState mandatory
Getting this variable will return the state of the outlet.
Valid return states are unknown, on, off, lockon, lockoff.
0 = off
1 = on
2 = reboot
3 = lockon (outlet is on and no changes are allowed)
4 = lockoff (outlet is…
Enumerationr/w
Enumerated Values:
0off
1on
2reboot
3lockon
4lockoff
5unlock
6unknown
.1.3.6.1.4.1.4779.1.3.5.6.1.4
sRPCOutletName mandatory
The name of the outlet. Maximum size is 16 characters.
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.4779.1.3.5.6.1.5
.1.3.6.1.4.1.4779.1.3.5.8 · 1 row entry · 5 columns
A list of total current for RPCs in each current group
sBTAModulesRPCCurrentGroupsCurrentEntry entry .1.3.6.1.4.1.4779.1.3.5.8.1
Table of total current measurement by group
Indexes
groupCurrentIndex
Column Syntax OID
groupCurrentIndex mandatory
The index to a group total current.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.3.5.8.1.1
groupCurrent mandatory
Current total for all RPCs in group.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.3.5.8.1.2
rpcGroup mandatory
A character string listing the RPCs, by port index, that will be
included in a measurement of total current. For each group, a sum
will be periodically computed of currents of all listed RPCs, which
will be compared to…
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.4779.1.3.5.8.1.3
warningThreshold mandatory
The current level, in tenths of an amp, that will cause a Current
Level Warning trap to be sent if the total current for the associated
group if exceeded. Conversely, a Current Level Warning Clear trap
will be sent w…
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.3.5.8.1.4
emergencyThreshold mandatory
The current level, in tenths of an amp, that will cause a Current
Level Emergency trap to be sent if the total current for the associated
group if exceeded. Conversely, a Current Level Emergeny Clear trap
will be sen…
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.3.5.8.1.5
.1.3.6.1.4.1.4779.1.3.5.9 · 1 row entry · 9 columns
Allows monitoring of individual outlet strips on RPCs.
sBTAModulesRPCBreakersEntry entry .1.3.6.1.4.1.4779.1.3.5.9.1
Status organization by breaker.
Indexes
sBTAModulesRPCBreakersModulesIndex sBTAModulesRPCBreakersBreakersIndex
Column Syntax OID
sBTAModulesRPCBreakersModulesIndex mandatory
The index into the RPC table.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.3.5.9.1.1
sBTAModulesRPCBreakersBreakersIndex mandatory
The index into the RPC breaker table.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.3.5.9.1.2
sBTAModulesRPCBreakersCircuitBreaker mandatory
Status of circuit breaker in power strip. 0=off 1=on.
Enumeration
Enumerated Values:
0off
1on
.1.3.6.1.4.1.4779.1.3.5.9.1.3
sBTAModulesRPCBreakersCurrent mandatory
The detected current reading for the power strip.
If current measurement is not installed this value will always read 0.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.3.5.9.1.4
sBTAModulesRPCBreakersMaxCurrent mandatory
The maximum detected current reading for the power strip.
If current measurement is not installed this value will always read 0.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.3.5.9.1.5
sBTAModulesRPCBreakersVoltage mandatory
The voltage reading for the power strip.
If voltage measurement is not installed this value will always read 0.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.3.5.9.1.6
sBTAModulesRPCBreakersPower mandatory
The power reading for the power strip.
If voltage measurement is not installed this value will always read 0.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.3.5.9.1.7
sBTAModulesRPCBreakersVA mandatory
The volt-amps reading for the power strip.
If voltage measurement is not installed this value will always read 0.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.3.5.9.1.8
sBTAModulesRPCBreakersCurrentAlarmThreshold mandatory
The current alarm threshold level *10. A value of 105 will set the level to 10.5.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.3.5.9.1.9
.1.3.6.1.4.1.4779.1.3.5.10 · 1 row entry · 10 columns
Allows monitoring of individual outlet strips on RPCs.
sRPCModPortBreakersEntry entry .1.3.6.1.4.1.4779.1.3.5.10.1
Status organization by breaker.
Indexes
sRPCBreakersModIndex sRPCBreakersPortIndex sRPCBreakersBreakersIndex
Column Syntax OID
sRPCBreakersModIndex mandatory
The module index into the RPC breaker table.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.3.5.10.1.1
sRPCBreakersPortIndex mandatory
The port index into the RPC breaker table.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.3.5.10.1.2
sRPCBreakersBreakersIndex mandatory
The breaker index into the RPC breaker table.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.3.5.10.1.3
sRPCBreakersCircuitBreaker mandatory
Status of circuit breaker in power strip. 0=off 1=on.
Enumeration
Enumerated Values:
0off
1on
.1.3.6.1.4.1.4779.1.3.5.10.1.4
sRPCBreakersCurrent mandatory
The detected current reading for the power strip.
If current measurement is not installed this value will always read 0.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.3.5.10.1.5
sRPCBreakersMaxCurrent mandatory
The maximum detected current reading for the power strip.
If current measurement is not installed this value will always read 0.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.3.5.10.1.6
sRPCBreakersVoltage mandatory
The voltage reading for the power strip.
If voltage measurement is not installed this value will always read 0.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.3.5.10.1.7
sRPCBreakersPower mandatory
The power reading for the power strip.
If voltage measurement is not installed this value will always read 0.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.3.5.10.1.8
sRPCBreakersVA mandatory
The volt-amps reading for the power strip.
If voltage measurement is not installed this value will always read 0.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.3.5.10.1.9
sRPCBreakersCurrentAlarmThreshold mandatory
The current alarm threshold level x10. A value of 105 will set the level to 10.5.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.3.5.10.1.10

sBTAControlUserTable

table mandatory
.1.3.6.1.4.1.4779.1.4.4 · 1 row entry · 7 columns
A list of users and user information.
The number of entries is contained in the sBTAControlNumOfLoggedUsers OID.
sBTAControlUserEntry entry .1.3.6.1.4.1.4779.1.4.4.1
The users to get status on.
Indexes
sBTAControlUserIndex
Column Syntax OID
sBTAControlUserIndex mandatory
The index to the user entry.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.4.4.1.1
sBTAControlUserName mandatory
The username of the user.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.4779.1.4.4.1.2
sBTAControlUserAddress mandatory
The IP address of the user.
RFC1155-SMIIpAddress
Textual Convention: RFC1155-SMIIpAddress OctetString
Type Constraints:
range: 4
.1.3.6.1.4.1.4779.1.4.4.1.3
sBTAControlUserConnection mandatory
Type of connection.
If unknown, user is logging out or the connection is invalid.
Enumeration
Enumerated Values:
0serialport
1telnet
2ssh
4unknown
.1.3.6.1.4.1.4779.1.4.4.1.4
sBTAControlUserConnModule mandatory
If the user is connected to a module, this value will
report the module number connected to.
If the value is 0 the user is not connected to a module.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.4.4.1.5
sBTAControlUserConnPort mandatory
The port number with in a module that the user is connected to.
This usually only applies to connections to DS74 serial modules.
Intelligent modules connections are always made on port 1.
If value is 0 the user is not c…
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.4.4.1.6
sBTAControlUserTerminateUser mandatory
Settings this OID to anything but 0 will terminate (log out) the user.
A get of this OID will return 0.
Enumerationr/w
Enumerated Values:
1terminate
.1.3.6.1.4.1.4779.1.4.4.1.7
.1.3.6.1.4.1.4779.1.6.1 · 1 row entry · 12 columns
Allows monitoring of individual outlet strips on RPCs.
sBTAModulesEnvironmentalObjectsEntry entry .1.3.6.1.4.1.4779.1.6.1.1
Status organization by sensor.
Indexes
sBTAModulesEnvironmentalModulesIndex sBTAModulesEnvironmentalSensorsIndex
Column Syntax OID
sBTAModulesEnvironmentalModulesIndex mandatory
Module Index for Environemntal table
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.6.1.1.1
sBTAModulesEnvironmentalSensorsIndex mandatory
Sensor Index for Environemntal table
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.6.1.1.2
sBTAModulesEnvironmentalType mandatory
Environmental Object Type.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.6.1.1.3
sBTAModulesEnvironmentalName mandatory
The name for the environmental object.
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.4779.1.6.1.1.4
sBTAModulesEnvironmentalMeasurement mandatory
The measurement or state for the object.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.6.1.1.5
sBTAModulesEnvironmentalHiThreshold mandatory
Hi threshold for object.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.6.1.1.6
sBTAModulesEnvironmentalLoThreshold mandatory
Lo threshold for object.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.6.1.1.7
sBTAModulesEnvironmentalMax mandatory
Max value recorded for object since last reset.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.6.1.1.8
sBTAModulesEnvironmentalMin mandatory
Min value recorded for object since last reset.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.6.1.1.9
sBTAModulesEnvironmentalHiThresholdEn mandatory
Hi threshold enable for object.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.6.1.1.10
sBTAModulesEnvironmentalLoThresholdEn mandatory
Lo threshold enable for object.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.6.1.1.11
sBTAModulesEnvironmentalStateTrapEn mandatory
Trap enable for environmental sensors with contacts.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.6.1.1.12
.1.3.6.1.4.1.4779.1.6.2 · 1 row entry · 13 columns
Allows monitoring of individual outlet strips on RPCs.
sRPCEnvironmentalObjectsEntry entry .1.3.6.1.4.1.4779.1.6.2.1
Status organization by sensor.
Indexes
sBTAEnvironmentalModuleIndex sBTAEnvironmentalPortIndex sBTAEnvironmentalSensorsIndex
Column Syntax OID
sRPCEnvironmentalModuleIndex mandatory
Module Index for Environemntal table
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.6.2.1.1
sRPCEnvironmentalPortIndex mandatory
Port Index for Environemntal table
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.6.2.1.2
sRPCEnvironmentalSensorsIndex mandatory
Sensor Index for Environemntal table
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.6.2.1.3
sRPCEnvironmentalType mandatory
Environmental Object Type.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.6.2.1.4
sRPCEnvironmentalName mandatory
The name for the environmental object.
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.4779.1.6.2.1.5
sRPCEnvironmentalMeasurement mandatory
The measurement or state for the object.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.6.2.1.6
sRPCEnvironmentalHiThreshold mandatory
Hi threshold for object.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.6.2.1.7
sRPCEnvironmentalLoThreshold mandatory
Lo threshold for object.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.6.2.1.8
sRPCEnvironmentalMax mandatory
Max value recorded for object since last reset.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.6.2.1.9
sRPCEnvironmentalMin mandatory
Min value recorded for object since last reset.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.6.2.1.10
sRPCEnvironmentalHiThresholdEn mandatory
Hi threshold enable for object.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.6.2.1.11
sRPCEnvironmentalLoThresholdEn mandatory
Lo threshold enable for object.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.6.2.1.12
sRPCEnvironmentalStateTrapEn mandatory
Trap enable for environmental sensors with contacts.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4779.1.6.2.1.13