usrListTable
table.1.3.6.1.4.1.21317.1.3.2.2.1.1
·
1 row entry
·
47 columns
A list of user. The number of user is given by the value of usrcfgNumber.
Status and parameter values for a pe8208 user.
Indexes
usrIndex
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
usrIndex
The value of usrIndex for the user. We have 1 administrator and 8 users.
The index 9 will be the administrator. |
Integer32 Constraints: range: 1-9 |
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.1 |
||||||||
|
usrType
The user's type.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.2 |
||||||||
|
usrName
A textual string containing name of the user.
string length: 1~16 |
OctetStringr/w Constraints: range: 1-16 |
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.3 |
||||||||
|
usrPassword
A textual string containing password of the user.
string length: 1~16 |
OctetStringr/w Constraints: range: 1-16 |
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.4 |
||||||||
|
usrPort1Auth
Display or set this user's outlet 1 authority.
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.5 |
||||||||
|
usrPort2Auth
Display or set this user's outlet 2 authority.
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.6 |
||||||||
|
usrPort3Auth
Display or set this user's outlet 3 authority.
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.7 |
||||||||
|
usrPort4Auth
Display or set this user's outlet 4 authority.
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.8 |
||||||||
|
usrPort5Auth
Display or set this user's outlet 5 authority.
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.9 |
||||||||
|
usrPort6Auth
Dispaly or set this user's outlet 6 authority.
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.10 |
||||||||
|
usrPort7Auth
Display or set this user's outlet 7 authority.
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.11 |
||||||||
|
usrPort8Auth
Display or set this user's outlet 8 authority.
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.12 |
||||||||
|
usrPort9Auth
Display or set this user's outlet 9 authority.
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.13 |
||||||||
|
usrPort10Auth
Display or set this user's outlet 10 authority.
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.14 |
||||||||
|
usrPort11Auth
Display or set this user's outlet 11 authority.
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.15 |
||||||||
|
usrPort12Auth
Display or set this user's outlet 12 authority.
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.16 |
||||||||
|
usrPort13Auth
Display or set this user's outlet 13 authority.
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.17 |
||||||||
|
usrPort14Auth
Display or set this user's outlet 14 authority.
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.18 |
||||||||
|
usrPort15Auth
Display or set this user's outlet 15 authority.
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.19 |
||||||||
|
usrPort16Auth
Display or set this user's outlet 16 authority.
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.20 |
||||||||
|
usrPort17Auth
Display or set this user's outlet 17 authority.
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.21 |
||||||||
|
usrPort18Auth
Display or set this user's outlet 18 authority.
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.22 |
||||||||
|
usrPort19Auth
Display or set this user's outlet 19 authority.
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.23 |
||||||||
|
usrPort20Auth
Display or set this user's outlet 20 authority.
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.24 |
||||||||
|
usrPort21Auth
Display or set this user's outlet 21 authority.
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.25 |
||||||||
|
usrPort22Auth
Display or set this user's outlet 22 authority.
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.26 |
||||||||
|
usrPort23Auth
Display or set this user's outlet 23 authority.
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.27 |
||||||||
|
usrPort24Auth
Display or set this user's outlet 24 authority.
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.28 |
||||||||
|
usrPort25Auth
Display or set this user's outlet 25 authority.
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.29 |
||||||||
|
usrPort26Auth
Display or set this user's outlet 26 authority.
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.30 |
||||||||
|
usrPort27Auth
Display or set this user's outlet 27 authority.
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.31 |
||||||||
|
usrPort28Auth
Display or set this user's outlet 28 authority.
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.32 |
||||||||
|
usrPort29Auth
Display or set this user's outlet 29 authority.
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.33 |
||||||||
|
usrPort30Auth
Display or set this user's outlet 30 authority.
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.34 |
||||||||
|
usrPort31Auth
Display or set this user's outlet 31 authority
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.35 |
||||||||
|
usrPort32Auth
Display or set this user's outlet 32 authority
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.36 |
||||||||
|
usrPort33Auth
Display or set this user's outlet 33 authority
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.37 |
||||||||
|
usrPort34Auth
Display or set this user's outlet 34 authority
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.38 |
||||||||
|
usrPort35Auth
Display or set this user's outlet 35 authority
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.39 |
||||||||
|
usrPort36Auth
Display or set this user's outlet 36 authority
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.40 |
||||||||
|
usrPort37Auth
Display or set this user's outlet 37 authority
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.41 |
||||||||
|
usrPort38Auth
Display or set this user's outlet 38 authority
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.42 |
||||||||
|
usrPort39Auth
Display or set this user's outlet 39 authority
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.43 |
||||||||
|
usrPort40Auth
Display or set this user's outlet 40 authority
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.44 |
||||||||
|
usrPort41Auth
Display or set this user's outlet 41 authority
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.45 |
||||||||
|
usrPort42Auth
Display or set this user's outlet 42 authority
Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.46 |
||||||||
|
usrEnable
Display or set this user is enable or not
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.1.1.1.47 |
deviceValueTable
table.1.3.6.1.4.1.21317.1.3.2.2.2.1.3
·
1 row entry
·
9 columns
Device value table. This table displays device's current, voltage, power and power dissipation.
Single deviceValue entry containing device info.
Indexes
deviceValueIndex
| Column | Syntax | OID |
|---|---|---|
|
deviceValueIndex
Index of deviceValue.
|
Integer32 Constraints: range: 1-1 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.3.1.1 |
|
deviceCurrent
Device electric current value.
If this measurement value is not available, it returns: N/A. If the device does not support this OID, it returns: not-support. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.3.1.2 |
|
deviceVoltage
Device voltage value.
If this measurement value is not available, it returns: N/A. If the device does not support this OID, it returns: not-support. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.3.1.3 |
|
devicePower
Device power value.
If this measurement value is not available, it returns: N/A. If the device does not support this OID, it returns: not-support. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.3.1.4 |
|
devicePowerDissipation
Device power dissipation value.
If this measurement value is not available, it returns: N/A. If the device does not support this OID, it returns: not-support. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.3.1.5 |
|
inputMaxVoltage
Device input Voltage value. unit:(V)
If the device does not support this OID, we show value 0. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.3.1.6 |
|
inputMaxCurrent
Device input Current value. unit:(A)
If the device does not support this OID, we show value 0. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.3.1.7 |
|
powerCapacity
Device power Capacity value.unit:(VA)
If the device does not support this OID, we show value 0. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.3.1.8 |
|
devicePowerFactor
Device power Factor value.
If the device does not support this OID, it returns: not-support. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.3.1.9 |
sensorValueTable
table.1.3.6.1.4.1.21317.1.3.2.2.2.1.4
·
1 row entry
·
5 columns
Device's sensor value table. This table displays sensor's temperature, humidity and pressure.
Single device's sensor value entry containing device info.
Indexes
sensorValueIndex
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
sensorValueIndex
Index of sensor number.
|
Integer32 Constraints: range: 1-6 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.4.1.1 |
||||||
|
sensorTemperature
Sensor's Temperature value.
If this measurement value is not available, it returns: N/A. If the device does not support this OID, it returns: not-support. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.4.1.2 |
||||||
|
sensorHumidity
Sensor's Humidity value.
If this measurement value is not available, it returns: N/A. If the device does not support this OID, it returns: not-support. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.4.1.3 |
||||||
|
sensorPressure
Sensor's Pressure value.
If this measurement value is not available, it returns: N/A. If the device does not support this OID, it returns: not-support. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.4.1.4 |
||||||
|
sensorProperty
Sensor's Property.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.2.1.4.1.5 |
deviceOutletStatusTable
table.1.3.6.1.4.1.21317.1.3.2.2.2.1.5
·
1 row entry
·
2 columns
Device outlet status value table.
Single deviceOutletStatus entry containing device info.
Indexes
deviceOutletStatusIndex
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
deviceOutletStatusIndex
Index of deviceOutletStatus
|
Integer32 Constraints: range: 1-30 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.5.1.1 |
||||||||||||||
|
displayOutletStatus
Display outlet status.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.2.1.5.1.2 |
deviceConfigTable
table.1.3.6.1.4.1.21317.1.3.2.2.2.1.6
·
1 row entry
·
8 columns
Device configuration table
Single deviceConfig entry containing device info.
Indexes
deviceConfigIndex
| Column | Syntax | OID |
|---|---|---|
|
deviceConfigIndex
Index of deviceConfig
|
Integer32 Constraints: range: 1-1 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.6.1.1 |
|
deviceMinCurMT
Display or set device minimum electric current measurement threshold.
Example: range 0.0~32.0 represents 0~320. NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device does … |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.6.1.2 |
|
deviceMaxCurMT
Display or set device maximum electric current measurement threshold.
Example: range 0.0~32.0 represents 0~320 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device doe… |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.6.1.3 |
|
deviceMinVolMT
Display or set device minimum voltage measurement threshold.
Exapmple: range 90.0~260.0 represents 900~2600 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device does not… |
Integer32r/w Constraints: range: 900-2600range: -3000--3000 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.6.1.4 |
|
deviceMaxVolMT
Display or set device maximum voltage measurement threshold.
Example: range 90.0~260.0 represents 900~2600 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device does not … |
Integer32r/w Constraints: range: 900-2600range: -3000--3000 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.6.1.5 |
|
deviceMinPMT
Display or set device minimum power measurement threshold.
Example: range 0.0 ~ 9999.9 represents 0~99999 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device does not s… |
Integer32r/w Constraints: range: 0-99999range: -3000--3000 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.6.1.6 |
|
deviceMaxPMT
Display or set device maximum power measurement threshold.
Example: range 0.0 ~ 9999.9 represents 0~99999 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device does not s… |
Integer32r/w Constraints: range: 0-99999range: -3000--3000 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.6.1.7 |
|
deviceMaxPDMT
Display or set device maximum power dissipation measurement threshold.
Example: range 0.0 ~ 99999.0 represents 0~999990 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the dev… |
Integer32r/w Constraints: range: 0-999990range: -3000--3000 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.6.1.8 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.7
·
1 row entry
·
7 columns
Device environment value table
Device's sensor Environment entry containing sensor info.
Indexes
deviceSensorTresholdIndex
| Column | Syntax | OID |
|---|---|---|
|
deviceSensorTresholdIndex
Index of sensor number
|
Integer32 Constraints: range: 1-6 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.7.1.1 |
|
sensorMinTempMT
Display or set sensor minimum temperature measurement threshold.
Example: range -20.0 ~ 60.0 represents -200~600 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device doe… |
Integer32r/w Constraints: range: -200-600range: -3000--3000 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.7.1.2 |
|
sensorMaxTempMT
Display or set sensor maximum temperature measurement threshold.
Example: range -20.0 ~ 60.0 represents -200~600 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device doe… |
Integer32r/w Constraints: range: -200-600range: -3000--3000 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.7.1.3 |
|
sensorMinHumMT
Display or set sensor minimum humidity measurement threshold.
Example: range 10.0 ~ 95.0 represents 100~950 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device does not… |
Integer32r/w Constraints: range: 100-950range: -3000--3000 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.7.1.4 |
|
sensorMaxHumMT
Display or set sensor maximum humidity measurement threshold.
Example: range 10.0 ~ 95.0 represents 100~950 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device does not… |
Integer32r/w Constraints: range: -3000--3000range: 100-950 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.7.1.5 |
|
sensorMinPressMT
Display or set sensor minimum pressure measurement threshold.
Example: range -250.0 ~ 250.0 represents -2500 ~ 2500 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device … |
Integer32r/w Constraints: range: -2500-2500range: -3000--3000 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.7.1.6 |
|
sensorMaxPressMT
Display or set sensor maximum pressure measurement threshold.
Example: range -250.0 ~ 250.0 represents -2500 ~ 2500 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device … |
Integer32r/w Constraints: range: -2500-2500range: -3000--3000 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.7.1.7 |
dryContactTable
table.1.3.6.1.4.1.21317.1.3.2.2.2.1.15
·
1 row entry
·
3 columns
Device's Dry Contact table.
Single device's dry contact value entry containing device info.
Indexes
dryContactIndex
| Column | Syntax | OID | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
dryContactIndex
Index of dry contact number.
|
Integer32 Constraints: range: 1-2 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.15.1.1 |
||||||||||
|
dryContactStatus
Display dry contact status.
close(0) represents door close. open(1) represents door open. not-attached(2) represents door sensor don't attach to device. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.2.1.15.1.2 |
||||||||||
|
dryContactType
Dry contact Type Selection
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.2.1.15.1.3 |
outletCAPTable
table.1.3.6.1.4.1.21317.1.3.2.2.2.1.18.2
·
1 row entry
·
2 columns
Outlet CAP table
Outlet CAP entry containing CAP info.
Indexes
outletCAPIndex
| Column | Syntax | OID |
|---|---|---|
|
outletCAPIndex
Index of outlet's CAP configuration
|
Integer32 Constraints: range: 1-40 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.18.2.1.1 |
|
outletCAPPriority
Display or set the CAP Priority of outlet.
Priority 0 means this outlet does not support this OID. |
Integer32r/w Constraints: range: 0-99 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.18.2.1.2 |
deviceIntegerValueTable
table.1.3.6.1.4.1.21317.1.3.2.2.2.1.99
·
1 row entry
·
5 columns
Device value table. This table displays device's current, voltage, power and power dissipation.
Single deviceValue entry containing device info.
Indexes
deviceIntegerValueIndex
| Column | Syntax | OID |
|---|---|---|
|
deviceIntegerValueIndex
Index of deviceValue.
|
Integer32 Constraints: range: 1-1 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.99.1.1 |
|
deviceIntegerCurrent
Device electric current value.
This value indicates that 1,000 times. If the device does not support this OID, it returns value -2000000. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.99.1.2 |
|
deviceIntegerVoltage
Device voltage value.
This value indicates that 1,000 times. If the device does not support this OID, it returns value -2000000. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.99.1.3 |
|
deviceIntegerPower
Device power value.
This value indicates that 1,000 times. If the device does not support this OID, it returns value -2000000. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.99.1.4 |
|
deviceIntegerPowerDissipation
Device power dissipation value.
This value indicates that 1,000 times. If the device does not support this OID, it returns value -2000000. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.99.1.5 |
sensorIntegerValueTable
table.1.3.6.1.4.1.21317.1.3.2.2.2.1.100
·
1 row entry
·
4 columns
Device's sensor value table. This table displays sensor's temperature, humidity and pressure.
Single device's sensor value entry containing device info.
Indexes
sensorIntegerValueIndex
| Column | Syntax | OID |
|---|---|---|
|
sensorIntegerValueIndex
Index of sensor number.
|
Integer32 Constraints: range: 1-6 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.100.1.1 |
|
sensorIntegerTemperature
Sensor's Temperature value.
This value indicates that 1,000 times. If this measurement value is not available, it returns value -1000000. If the device does not support this OID, it returns value -2000000. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.100.1.2 |
|
sensorIntegerHumidity
Sensor's Humidity value.
This value indicates that 1,000 times. If this measurement value is not available, it returns value -1000000. If the device does not support this OID, it returns value -2000000. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.100.1.3 |
|
sensorIntegerPressure
Sensor's Pressure value.
This value indicates that 1,000 times. If this measurement value is not available, it returns value -1000000. If the device does not support this OID, it returns value -2000000. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.2.2.1.100.1.4 |
outletValueTable
table.1.3.6.1.4.1.21317.1.3.2.2.2.2.1
·
1 row entry
·
7 columns
Display total outlet value table
Single outletValue entry containing outlet info.
Indexes
outletValueIndex
| Column | Syntax | OID |
|---|---|---|
|
outletValueIndex
Index of outlet number
|
Integer32 Constraints: range: 1-30 |
.1.3.6.1.4.1.21317.1.3.2.2.2.2.1.1.1 |
|
outletCurrent
Outlet electric current value.
If this measurement value is not available, it returns: N/A. If the device does not support this OID, it returns: not-support. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.21317.1.3.2.2.2.2.1.1.2 |
|
outletVoltage
Outlet voltage value.
If this measurement value is not available, it returns: N/A. If the device does not support this OID, it returns: not-support. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.21317.1.3.2.2.2.2.1.1.3 |
|
outletPower
Outlet power value.
If this measurement value is not available, it returns: N/A. If the device does not support this OID, it returns: not-support. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.21317.1.3.2.2.2.2.1.1.4 |
|
outletPowerDissipation
Outlet power dissipation value.
If this measurement value is not available, it returns: N/A. If the device does not support this OID, it returns: not-support. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.21317.1.3.2.2.2.2.1.1.5 |
|
outletMaxCurrent
Outlet Max Current value. unit: (A).
If the device does not support this OID, we show value 0. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.2.2.2.1.1.6 |
|
outletPowerFactor
Outlet Power Factor value.
If the device does not support this OID, it returns: not-support. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.21317.1.3.2.2.2.2.1.1.7 |
outletConfigTable
table.1.3.6.1.4.1.21317.1.3.2.2.2.2.10
·
1 row entry
·
16 columns
Outlet configuration table
Outlet Config entry containing outlet info.
Indexes
outletConfigIndex
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
outletConfigIndex
Index of outlet number
|
Integer32 Constraints: range: 1-30 |
.1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.1 |
||||||||
|
outletName
Display or set the name of outlet.
If the device does not support this OID, we show n/a. string length: 0~48 NOTE: Input string as /empty to set this object to NULL. |
RFC1213-MIBDisplayStringr/w Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.2 |
||||||||
|
outletConfirmation
Display or set the confirmation of outlet.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.3 |
||||||||
|
outletOnDelayTime
Display or set the ON delay time of outlet.
When this model does not support the OID, we show value -1. |
Integer32r/w Constraints: range: -1-999 |
.1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.4 |
||||||||
|
outletOffDelayTime
Display or set the OFF delay time of outlet.
When this model does not support the OID, we show value -1. |
Integer32r/w Constraints: range: -1-999 |
.1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.5 |
||||||||
|
outletShutdownMethod
Display or set the shutdown mehtod of outlet.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.6 |
||||||||
|
outletMAC
Display or set the MAC address of ShutdownMethod.
If the device does not support this OID, we show n/a. string length: 12 |
RFC1213-MIBDisplayStringr/w Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.7 |
||||||||
|
outletMinCurMT
Display or set the outlet minimum electric current measurment threshold.
Example: range 0.0 ~16.0 rerpresnts 0~160 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device d… |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.8 |
||||||||
|
outletMaxCurMT
Display or set the outlet maximum electric current measurment threshold.
Example: range 0.0 ~16.0 represents 0~160 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device d… |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.9 |
||||||||
|
outletMinVolMT
Display or set the outlet minimum voltage measurment threshold.
Example: range 90.0 ~260.0 represents 900~2600 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device does … |
Integer32r/w Constraints: range: 900-2600range: -3000--3000range: -2000000--2000000 |
.1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.10 |
||||||||
|
outletMaxVolMT
Display or set the outlet maximum voltage measurment threshold.
Example: range 90.0 ~260.0 represents 900~2600 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device does … |
Integer32r/w Constraints: range: 900-2600range: -3000--3000range: -2000000--2000000 |
.1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.11 |
||||||||
|
outletMinPMT
Display or set the outlet minimum power measurment threshold.
Example: range 0.0 ~ 9999.9 represents 0~99999 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device does not… |
Integer32r/w Constraints: range: 0-99999range: -3000--3000range: -2000000--2000000 |
.1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.12 |
||||||||
|
outletMaxPMT
Display or set the outlet maximum power measurment threshold.
Example: range 0.0 ~ 9999.9 represents 0~99999 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device does not… |
Integer32r/w Constraints: range: 0-99999range: -3000--3000range: -2000000--2000000 |
.1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.13 |
||||||||
|
outletMaxPDMT
Display or set the outlet maximum power dissipation measurment threshold.
Example: range 0.0 ~ 99999.0 represents 0~999990 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the d… |
Integer32r/w Constraints: range: 0-999990range: -3000--3000range: -2000000--2000000 |
.1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.14 |
||||||||
|
outletLocalAccessLock
Whether local access of Outlet is locked by remote or not.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.15 |
||||||||
|
outletAlwaysON
Whether the outlet is always ON or not.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.16 |
outletSwitchableTable
table.1.3.6.1.4.1.21317.1.3.2.2.2.2.70
·
1 row entry
·
2 columns
Indexes
outletSwitchableIndex
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
outletSwitchableIndex
Index of outlet number.
|
Integer32 Constraints: range: 1-30 |
.1.3.6.1.4.1.21317.1.3.2.2.2.2.70.1.1 |
||||
| outletSwitchable | Enumeration Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.2.2.70.1.2 |
outletIntegerValueTable
table.1.3.6.1.4.1.21317.1.3.2.2.2.2.99
·
1 row entry
·
5 columns
Display total outlet value table
Single outletValue entry containing outlet info.
Indexes
outletIntegerValueIndex
| Column | Syntax | OID |
|---|---|---|
|
outletIntegerValueIndex
Index of outlet number.
|
Integer32 Constraints: range: 1-30 |
.1.3.6.1.4.1.21317.1.3.2.2.2.2.99.1.1 |
|
outletIntegerCurrent
Outlet electric current value.
This value indicates that 1,000 times. If the device does not support this OID, it returns value -2000000. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.2.2.2.99.1.2 |
|
outletIntegerVoltage
Outlet voltage value.
This value indicates that 1,000 times. If the device does not support this OID, it returns value -2000000. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.2.2.2.99.1.3 |
|
outletIntegerPower
Outlet power value.
This value indicates that 1,000 times. If the device does not support this OID, it returns value -2000000. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.2.2.2.99.1.4 |
|
outletIntegerPowerDissipation
Outlet power dissipation value.
This value indicates that 1,000 times. If the device does not support this OID, it returns value -2000000. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.2.2.2.99.1.5 |
breakerStatusTable
table.1.3.6.1.4.1.21317.1.3.2.2.2.3.1
·
1 row entry
·
2 columns
Display total bank value table
Single bankValue entry containing bank info.
Indexes
breakerStatusIndex
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
breakerStatusIndex
Index of breaker number.
|
Integer32 Constraints: range: 1-30 |
.1.3.6.1.4.1.21317.1.3.2.2.2.3.1.1.1 |
||||||
|
breakerStatus
Breaker status.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.2.3.1.1.2 |
bankValueTable
table.1.3.6.1.4.1.21317.1.3.2.2.2.3.2
·
1 row entry
·
8 columns
Display total bank value table
Single bankValue entry containing bank info.
Indexes
bankValueIndex
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
bankValueIndex
Index of bank number
|
Integer32 Constraints: range: 1-30 |
.1.3.6.1.4.1.21317.1.3.2.2.2.3.2.1.1 |
||||||||
|
bankCurrent
Bank electric current value.
If this measurement value is not available, it returns: N/A. If the device does not support this OID, it returns: not-support. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.21317.1.3.2.2.2.3.2.1.2 |
||||||||
|
bankVoltage
Bank voltage value.
We put this OID to write access type for user to set the reference voltage on EC1000 model. And the setting should be the numbers. You can set 0 to clear the setting. If this measurement value is not… |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.21317.1.3.2.2.2.3.2.1.3 |
||||||||
|
bankPower
Bank power value.
If this measurement value is not available, it returns: N/A. If the device does not support this OID, it returns: not-support. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.21317.1.3.2.2.2.3.2.1.4 |
||||||||
|
bankPowerDissipation
Bank power dissipation value.
If this measurement value is not available, it returns: N/A. If the device does not support this OID, it returns: not-support. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.21317.1.3.2.2.2.3.2.1.5 |
||||||||
|
bankMaxCurrent
The Bank Max Current value. unit: (A)
EC1000:0A~320A |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.2.2.3.2.1.6 |
||||||||
|
bankAttachStatus
The status of Energy sensor Bank attached status.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.2.3.2.1.7 |
||||||||
|
bankPowerFactor
Bank Power Factor value.
If the device does not support this OID, it returns: not-support. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.21317.1.3.2.2.2.3.2.1.8 |
bankConfigTable
table.1.3.6.1.4.1.21317.1.3.2.2.2.3.3
·
1 row entry
·
9 columns
Bank configuration table
Bank Config entry containing Bank info.
Indexes
bankConfigIndex
| Column | Syntax | OID |
|---|---|---|
|
bankConfigIndex
Index of bank number
|
Integer32 Constraints: range: 1-30 |
.1.3.6.1.4.1.21317.1.3.2.2.2.3.3.1.1 |
|
bankName
Display or set the name of bank.
When this model does not support the OID, we show n/a. string length: 0~15 NOTE: Input string as /empty to set this object to NULL. |
RFC1213-MIBDisplayStringr/w Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.21317.1.3.2.2.2.3.3.1.2 |
|
bankMinCurMT
Display or set the outlet minimum electric current measurment threshold.
Example: range 0.0 ~16.0 rerpresnts 0~160 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device d… |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.2.2.3.3.1.3 |
|
bankMaxCurMT
Display or set the outlet maximum electric current measurment threshold.
Example: range 0.0 ~16.0 represents 0~160 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device d… |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.2.2.3.3.1.4 |
|
bankMinVolMT
Display or set the outlet minimum voltage measurment threshold.
Example: range 90.0 ~260.0 represents 900~2600 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device does … |
Integer32r/w Constraints: range: 900-2600range: -3000--3000range: -2000000--2000000 |
.1.3.6.1.4.1.21317.1.3.2.2.2.3.3.1.5 |
|
bankMaxVolMT
Display or set the outlet maximum voltage measurment threshold.
Example: range 90.0 ~260.0 represents 900~2600 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device does … |
Integer32r/w Constraints: range: 900-2600range: -3000--3000range: -2000000--2000000 |
.1.3.6.1.4.1.21317.1.3.2.2.2.3.3.1.6 |
|
bankMinPMT
Display or set the outlet minimum power measurment threshold.
Example: range 0.0 ~ 9999.9 represents 0~99999 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device does not… |
Integer32r/w Constraints: range: 0-99999range: -3000--3000range: -2000000--2000000 |
.1.3.6.1.4.1.21317.1.3.2.2.2.3.3.1.7 |
|
bankMaxPMT
Display or set the outlet maximum power measurment threshold.
Example: range 0.0 ~ 9999.9 represents 0~99999 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the device does not… |
Integer32r/w Constraints: range: 0-99999range: -3000--3000range: -2000000--2000000 |
.1.3.6.1.4.1.21317.1.3.2.2.2.3.3.1.8 |
|
bankMaxPDMT
Display or set the outlet maximum power dissipation measurment threshold.
Example: range 0.0 ~ 99999.0 represents 0~999990 NOTICE: Minimum threshold should be smaller than maximum threshold. Empty value: -3000. If the d… |
Integer32r/w Constraints: range: 0-999990range: -3000--3000range: -2000000--2000000 |
.1.3.6.1.4.1.21317.1.3.2.2.2.3.3.1.9 |
bankControlTable
table.1.3.6.1.4.1.21317.1.3.2.2.2.3.4
·
1 row entry
·
2 columns
Bank Control table
Bank control entry.
Indexes
bankControlIndex
| Column | Syntax | OID | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
bankControlIndex
Index of bank number
|
Integer32 Constraints: range: 1-4 |
.1.3.6.1.4.1.21317.1.3.2.2.2.3.4.1.1 |
||||||||||
|
bankControlStatus
This function is used for outlet control of bank.
Set off(1) to turn off for outlet control of bank. Set on(2) to turn on for all outlet control of bank. Set reboot(3) to turn on for outlet control of bank. Get this obj… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.21317.1.3.2.2.2.3.4.1.2 |
bankIntegerValueTable
table.1.3.6.1.4.1.21317.1.3.2.2.2.3.99
·
1 row entry
·
5 columns
Display total bank value table
Single bankValue entry containing bank info.
Indexes
bankIntegerValueIndex
| Column | Syntax | OID |
|---|---|---|
|
bankIntegerValueIndex
Index of bank number.
|
Integer32 Constraints: range: 1-30 |
.1.3.6.1.4.1.21317.1.3.2.2.2.3.99.1.1 |
|
bankIntegerCurrent
Bank electric current value.
This value indicates that 1,000 times. If this measurement value is not available, it returns value -1000000. If the device does not support this OID, it returns value -2000000. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.2.2.3.99.1.2 |
|
bankIntegerVoltage
Bank voltage value.
This value indicates that 1,000 times. We put this OID to write access type for user to set the reference voltage on EC1000 model. And the setting should be the numbers. You can set 0… |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.2.2.3.99.1.3 |
|
bankIntegerPower
Bank power value.
This value indicates that 1,000 times. If this measurement value is not available, it returns value -1000000. If the device does not support this OID, it returns value -2000000. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.2.2.3.99.1.4 |
|
bankIntegerPowerDissipation
Bank power dissipation value.
This value indicates that 1,000 times. If this measurement value is not available, it returns value -1000000. If the device does not support this OID, it returns value -2000000. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.21317.1.3.2.2.2.3.99.1.5 |
snmpTrapTable
table.1.3.6.1.4.1.21317.1.3.2.2.3.4.7.1.3
·
1 row entry
·
7 columns
PE SNMP agent trap setup table. If users want to use trap, they must set enable trap, ip and community first.
Single trap entry containing trap receiver info.
Indexes
trapReceiverNumber
| Column | Syntax | OID |
|---|---|---|
|
trapReceiverNumber
Index of trap receiver
|
Integer32 Constraints: range: 1-2 |
.1.3.6.1.4.1.21317.1.3.2.2.3.4.7.1.3.1.1 |
|
trapReceiverIPAddress
Trap receiver IP address
|
RFC1155-SMIIpAddressr/w Textual Convention: RFC1155-SMIIpAddress OctetStringType Constraints: range: 4 |
.1.3.6.1.4.1.21317.1.3.2.2.3.4.7.1.3.1.2 |
|
trapPort
NMS trap port to be used by agent to send trap
|
Integer32r/w Constraints: range: 1-65535 |
.1.3.6.1.4.1.21317.1.3.2.2.3.4.7.1.3.1.3 |
|
trapCommunity
If use SNMPv1/v2c to receive trap should set this Community string.
MAX string length: 20 NOTE: Input string as /empty to set this object to NULL. |
OctetStringr/w Constraints: range: 0-20 |
.1.3.6.1.4.1.21317.1.3.2.2.3.4.7.1.3.1.4 |
|
trapUsername
If use SNMPv3 to receive trap should set this string.
NOTE: Input string as /empty to set this object to NULL. MAX string length: 20 |
OctetStringr/w Constraints: range: 0-20 |
.1.3.6.1.4.1.21317.1.3.2.2.3.4.7.1.3.1.5 |
|
trapAuthpassword
If use SNMPv3 to receive trap should set this string.
MAX string length: 20 NOTE: Input string as /empty to set this object to NULL. |
OctetStringr/w Constraints: range: 8-20 |
.1.3.6.1.4.1.21317.1.3.2.2.3.4.7.1.3.1.6 |
|
trapPrivpassword
If use SNMPv3 to receive trap should set this string.
MAX string length: 20 NOTE: Input string as /empty to set this object to NULL. |
OctetStringr/w Constraints: range: 8-20 |
.1.3.6.1.4.1.21317.1.3.2.2.3.4.7.1.3.1.7 |
ipFilterTable
table.1.3.6.1.4.1.21317.1.3.2.2.3.5.4.2.3
·
1 row entry
·
3 columns
A list of restricted ip.
Status and parameter values for a PE's restricted IP.
Indexes
ipFilterIndex
| Column | Syntax | OID |
|---|---|---|
|
ipFilterIndex
The value of index for the ip filter.
|
Integer32 Constraints: range: 1-5 |
.1.3.6.1.4.1.21317.1.3.2.2.3.5.4.2.3.1.1 |
|
ipFilterFrom
A set of restricted ip.
ex. 192.168.0.1 Note: Users must follow in order to set the ip address. Note: To clear the settings to set the ip 0.0.0.0 |
RFC1155-SMIIpAddressr/w Textual Convention: RFC1155-SMIIpAddress OctetStringType Constraints: range: 4 |
.1.3.6.1.4.1.21317.1.3.2.2.3.5.4.2.3.1.2 |
|
ipFilterTo
A set of restricted ip.
ex. 192.168.0.255 Note: Users must follow in order to set the ip address. Note: To clear the settings to set the ip 0.0.0.0 |
RFC1155-SMIIpAddressr/w Textual Convention: RFC1155-SMIIpAddress OctetStringType Constraints: range: 4 |
.1.3.6.1.4.1.21317.1.3.2.2.3.5.4.2.3.1.3 |
macFilterTable
table.1.3.6.1.4.1.21317.1.3.2.2.3.5.4.3.3
·
1 row entry
·
2 columns
A list of restricted mac.
Status and parameter values for a PE's restricted MAC.
Indexes
macFilterIndex
| Column | Syntax | OID |
|---|---|---|
|
macFilterIndex
The value of index for the mac filter.
|
Integer32 Constraints: range: 1-5 |
.1.3.6.1.4.1.21317.1.3.2.2.3.5.4.3.3.1.1 |
|
macFilterSet
A set of restricted mac.
string length: 12 ex. 004854655511 Note: Users must follow in order to set the MAC address. Note: To clear the settings to set the MAC 000000000000 |
RFC1213-MIBDisplayStringr/w Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.21317.1.3.2.2.3.5.4.3.3.1.2 |