ALPHA-INVERTER-SYS-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
3
Rows
3
Columns
32
invSysAcPhaseTable
table.1.3.6.1.4.1.7309.5.3.3.80.2
·
1 row entry
·
16 columns
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
invSysAcPhaseAcOutputPowerVa
The power of the AC output (VA).
|
ALPHA-RESOURCE-MIBScaledNumber Textual Convention: ALPHA-RESOURCE-MIBScaledNumber Integer32 |
.1.3.6.1.4.1.7309.5.3.3.80.2.1.1 |
|
invSysAcPhaseOutputVoltageMeasured
The output voltage of the phase or inverter (V).
|
ALPHA-RESOURCE-MIBScaledNumber Textual Convention: ALPHA-RESOURCE-MIBScaledNumber Integer32 |
.1.3.6.1.4.1.7309.5.3.3.80.2.1.2 |
|
invSysAcPhaseOutputCurrent
The output current of the phase or inverter (A).
|
ALPHA-RESOURCE-MIBScaledNumber Textual Convention: ALPHA-RESOURCE-MIBScaledNumber Integer32 |
.1.3.6.1.4.1.7309.5.3.3.80.2.1.3 |
|
invSysAcPhaseFrequency
Frequency to which the inverters will lock (Hz).
|
ALPHA-RESOURCE-MIBScaledNumber Textual Convention: ALPHA-RESOURCE-MIBScaledNumber Integer32 |
.1.3.6.1.4.1.7309.5.3.3.80.2.1.4 |
|
invSysAcPhaseLoadingOfInstalledPowerVa
The ratio of output load to installed power (%VA).
|
ALPHA-RESOURCE-MIBScaledNumber Textual Convention: ALPHA-RESOURCE-MIBScaledNumber Integer32 |
.1.3.6.1.4.1.7309.5.3.3.80.2.1.5 |
|
invSysAcPhaseNumberOfModulesOn
The number of inverters that are On and can deliver power.
|
ALPHA-RESOURCE-MIBScaledNumber Textual Convention: ALPHA-RESOURCE-MIBScaledNumber Integer32 |
.1.3.6.1.4.1.7309.5.3.3.80.2.1.6 |
|
invSysAcPhaseLoadingOfInstalledPowerWatts
The ratio of output load to installed power (% W).
|
ALPHA-RESOURCE-MIBScaledNumber Textual Convention: ALPHA-RESOURCE-MIBScaledNumber Integer32 |
.1.3.6.1.4.1.7309.5.3.3.80.2.1.7 |
|
invSysAcPhaseDcInputToOutputPowerRatioMeasured
The measured percentage of DC input power to output power(%). Under light or no load this value will not computed accurately.
|
ALPHA-RESOURCE-MIBScaledNumber Textual Convention: ALPHA-RESOURCE-MIBScaledNumber Integer32 |
.1.3.6.1.4.1.7309.5.3.3.80.2.1.8 |
|
invSysAcPhaseAcInputPowerWatts
The power drawn by the AC input (W).
|
ALPHA-RESOURCE-MIBScaledNumber Textual Convention: ALPHA-RESOURCE-MIBScaledNumber Integer32 |
.1.3.6.1.4.1.7309.5.3.3.80.2.1.9 |
|
invSysAcPhaseAcInputPowerVa
The power drawn by the AC input (VA).
|
ALPHA-RESOURCE-MIBScaledNumber Textual Convention: ALPHA-RESOURCE-MIBScaledNumber Integer32 |
.1.3.6.1.4.1.7309.5.3.3.80.2.1.10 |
|
invSysAcPhaseAcOutputPowerWatts
The power of the AC output (W).
|
ALPHA-RESOURCE-MIBScaledNumber Textual Convention: ALPHA-RESOURCE-MIBScaledNumber Integer32 |
.1.3.6.1.4.1.7309.5.3.3.80.2.1.11 |
|
invSysAcPhaseDCInputPowerWatts
The power drawn by the DC input (W).
|
ALPHA-RESOURCE-MIBScaledNumber Textual Convention: ALPHA-RESOURCE-MIBScaledNumber Integer32 |
.1.3.6.1.4.1.7309.5.3.3.80.2.1.12 |
|
invSysAcPhaseNumberOfRedundantModulesMeasured
Number of inverters currently unneeded by the load.
|
ALPHA-RESOURCE-MIBScaledNumber Textual Convention: ALPHA-RESOURCE-MIBScaledNumber Integer32 |
.1.3.6.1.4.1.7309.5.3.3.80.2.1.13 |
|
invSysAcPhaseNumberOfModulesDetected
The number of inverters assigned to this phase that the T2S has detected.
|
ALPHA-RESOURCE-MIBScaledNumber Textual Convention: ALPHA-RESOURCE-MIBScaledNumber Integer32 |
.1.3.6.1.4.1.7309.5.3.3.80.2.1.14 |
|
invSysAcPhaseNumberOfModulesOff
The number of inverters that are manually turned off.
|
ALPHA-RESOURCE-MIBScaledNumber Textual Convention: ALPHA-RESOURCE-MIBScaledNumber Integer32 |
.1.3.6.1.4.1.7309.5.3.3.80.2.1.15 |
|
invSysAcPhaseNumberOfModulesFailed
The number of inverters that have failed and cannot deliver power.
|
ALPHA-RESOURCE-MIBScaledNumber Textual Convention: ALPHA-RESOURCE-MIBScaledNumber Integer32 |
.1.3.6.1.4.1.7309.5.3.3.80.2.1.16 |
invSysAcInputTable
table.1.3.6.1.4.1.7309.5.3.3.81.2
·
1 row entry
·
9 columns
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
invSysAcInputInputVoltage
The input voltage of the inverter or group (V).
|
ALPHA-RESOURCE-MIBScaledNumber Textual Convention: ALPHA-RESOURCE-MIBScaledNumber Integer32 |
.1.3.6.1.4.1.7309.5.3.3.81.2.1.1 |
|
invSysAcInputInputCurrent
The input current of the inverter or group (A).
|
ALPHA-RESOURCE-MIBScaledNumber Textual Convention: ALPHA-RESOURCE-MIBScaledNumber Integer32 |
.1.3.6.1.4.1.7309.5.3.3.81.2.1.2 |
|
invSysAcInputFrequency
The frequency of the input voltage and current of the inverter or group (Hz).
|
ALPHA-RESOURCE-MIBScaledNumber Textual Convention: ALPHA-RESOURCE-MIBScaledNumber Integer32 |
.1.3.6.1.4.1.7309.5.3.3.81.2.1.3 |
|
invSysAcInputAcInputPowerVa
The power drawn by the AC input (VA).
|
ALPHA-RESOURCE-MIBScaledNumber Textual Convention: ALPHA-RESOURCE-MIBScaledNumber Integer32 |
.1.3.6.1.4.1.7309.5.3.3.81.2.1.4 |
|
invSysAcInputNumberOfModulesOn
The number of inverters that are On and can deliver power.
|
ALPHA-RESOURCE-MIBScaledNumber Textual Convention: ALPHA-RESOURCE-MIBScaledNumber Integer32 |
.1.3.6.1.4.1.7309.5.3.3.81.2.1.5 |
|
invSysAcInputAcInputPowerWatts
The power drawn by the AC input (W).
|
ALPHA-RESOURCE-MIBScaledNumber Textual Convention: ALPHA-RESOURCE-MIBScaledNumber Integer32 |
.1.3.6.1.4.1.7309.5.3.3.81.2.1.6 |
|
invSysAcInputNumberOfModulesDetected
The number of inverters assigned to this phase that the T2S has detected.
|
ALPHA-RESOURCE-MIBScaledNumber Textual Convention: ALPHA-RESOURCE-MIBScaledNumber Integer32 |
.1.3.6.1.4.1.7309.5.3.3.81.2.1.7 |
|
invSysAcInputNumberOfModulesOff
The number of inverters that are manually turned off.
|
ALPHA-RESOURCE-MIBScaledNumber Textual Convention: ALPHA-RESOURCE-MIBScaledNumber Integer32 |
.1.3.6.1.4.1.7309.5.3.3.81.2.1.8 |
|
invSysAcInputNumberOfModulesFailed
The number of inverters that have failed and cannot deliver power.
|
ALPHA-RESOURCE-MIBScaledNumber Textual Convention: ALPHA-RESOURCE-MIBScaledNumber Integer32 |
.1.3.6.1.4.1.7309.5.3.3.81.2.1.9 |
invSysDcInputTable
table.1.3.6.1.4.1.7309.5.3.3.82.2
·
1 row entry
·
7 columns
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
invSysDcInputInputVoltage
The input voltage of the inverter or group (V).
|
ALPHA-RESOURCE-MIBScaledNumber Textual Convention: ALPHA-RESOURCE-MIBScaledNumber Integer32 |
.1.3.6.1.4.1.7309.5.3.3.82.2.1.1 |
|
invSysDcInputInputCurrent
The input current of the inverter or group (A).
|
ALPHA-RESOURCE-MIBScaledNumber Textual Convention: ALPHA-RESOURCE-MIBScaledNumber Integer32 |
.1.3.6.1.4.1.7309.5.3.3.82.2.1.2 |
|
invSysDcInputDcInputPowerWatts
The power drawn by the DC input (W).
|
ALPHA-RESOURCE-MIBScaledNumber Textual Convention: ALPHA-RESOURCE-MIBScaledNumber Integer32 |
.1.3.6.1.4.1.7309.5.3.3.82.2.1.3 |
|
invSysDcInputNumberOfModulesOn
The number of inverters that are On and can deliver power.
|
ALPHA-RESOURCE-MIBScaledNumber Textual Convention: ALPHA-RESOURCE-MIBScaledNumber Integer32 |
.1.3.6.1.4.1.7309.5.3.3.82.2.1.4 |
|
invSysDcInputNumberOfModulesOff
The number of inverters that are manually turned off.
|
ALPHA-RESOURCE-MIBScaledNumber Textual Convention: ALPHA-RESOURCE-MIBScaledNumber Integer32 |
.1.3.6.1.4.1.7309.5.3.3.82.2.1.5 |
|
invSysDcInputNumberOfModulesFailed
The number of inverters that have failed and cannot deliver power.
|
ALPHA-RESOURCE-MIBScaledNumber Textual Convention: ALPHA-RESOURCE-MIBScaledNumber Integer32 |
.1.3.6.1.4.1.7309.5.3.3.82.2.1.6 |
|
invSysDcInputNumberOfModulesDetected
The number of inverters assigned to this phase that the T2S has detected.
|
ALPHA-RESOURCE-MIBScaledNumber Textual Convention: ALPHA-RESOURCE-MIBScaledNumber Integer32 |
.1.3.6.1.4.1.7309.5.3.3.82.2.1.7 |