ADTRAN-TA5K-FXS-FAC-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
1
Rows
1
Columns
3
.1.3.6.1.4.1.664.5.67.1.35.1
·
1 row entry
·
3 columns
The Limited THL test is used during the factory calibration of the TA5000 CPOTS Module (1187160F1). It sends three tones port port towards the CPOTS module, which should be off-hook, and measures the resultant Echo Return Loss (ERL).
...
Indexes
ADTRAN-GENSLOT-MIBadGenSlotInfoIndex
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
adTa5kFxsFacLimitedThlStart
Used to start the test.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.664.5.67.1.35.1.1.1 |
||||||||
|
adTa5kFxsFacLimitedThlStatus
Use to monitor test progress:
1 = na Returned when test has never been run. 2 = complete Returned once test has completed successfully. 3 = fault Returned if test aborted due to a failure. 4 = running … |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.664.5.67.1.35.1.1.2 |
||||||||
|
adTa5kFxsFacLimitedThlResults
Returns a vector of 32-bit unsigned integers (split into octets
containing the measured ERL for each port of the card under test in mdB units. The first uint32 is always empty. The first port can be found in the second … |
OctetString Constraints: range: 1-256 |
.1.3.6.1.4.1.664.5.67.1.35.1.1.3 |