ADTRAN-GEMINAX-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
1
Rows
1
Columns
6
.1.3.6.1.4.1.664.5.73.2.1.1 · 1 row entry · 6 columns
This table contains information on the Lantiq (Infineon)
GeminaxMax DSP. Each entry reflects a required
 parameter or action required to perform either the SELT
 or DELT diagnostic test.
adGenGeminaxDiagEntry entry .1.3.6.1.4.1.664.5.73.2.1.1.1
This table contains configuration parameters for the GeminaxMax DSP.
The entries are used to configure the recovery option settings.
Indexes
ADTRAN-GENSLOT-MIBadGenSlotInfoIndex
Column Syntax OID
adGenGeminaxErrorClassECF
Sets the action to be taken when a Class ECF error occurs. The following settings are allowed:
disabled(1) - do nothing,
logOnly(2) - log the event,
softReset(3) - trigger a soft reset,
hardReset(4) - trigger a hard res…
Enumerationr/w
Enumerated Values:
1disabled
2logOnly
3softReset
4hardReset
.1.3.6.1.4.1.664.5.73.2.1.1.1.1
adGenGeminaxErrorClassA
Sets the action to be taken when a Class A error occurs. The following settings are allowed:
disabled(1) - do nothing,
logOnly(2) - log the event,
softReset(3) - trigger a soft reset,
hardReset(4) - trigger a hard reset
Enumerationr/w
Enumerated Values:
1disabled
2logOnly
3softReset
4hardReset
.1.3.6.1.4.1.664.5.73.2.1.1.1.2
adGenGeminaxErrorClassB
Sets the action to be taken when a Class B error occurs. The following settings are allowed:
disabled(1) - do nothing,
logOnly(2) - log the event,
softReset(3) - trigger a soft reset,
hardReset(4) - trigger a hard reset
Enumerationr/w
Enumerated Values:
1disabled
2logOnly
3softReset
4hardReset
.1.3.6.1.4.1.664.5.73.2.1.1.1.3
adGenGeminaxErrorClassC
Sets the action to be taken when a Class C error occurs. The following settings are allowed:
disabled(1) - do nothing,
logOnly(2) - log the event,
softReset(3) - trigger a soft reset,
hardReset(4) - trigger a hard reset
Enumerationr/w
Enumerated Values:
1disabled
2logOnly
3softReset
4hardReset
.1.3.6.1.4.1.664.5.73.2.1.1.1.4
adGenGeminaxErrorClassD
Sets the action to be taken when a Class D error occurs. The following settings are allowed:
disabled(1) - do nothing,
logOnly(2) - log the event,
softReset(3) - trigger a soft reset,
hardReset(4) - trigger a hard reset
Enumerationr/w
Enumerated Values:
1disabled
2logOnly
3softReset
4hardReset
.1.3.6.1.4.1.664.5.73.2.1.1.1.5
adGenGeminaxErrorClassE
Sets the action to be taken when a Class E error occurs. The following settings are allowed:
disabled(1) - do nothing,
logOnly(2) - log the event,
softReset(3) - trigger a soft reset,
hardReset(4) - trigger a hard reset
Enumerationr/w
Enumerated Values:
1disabled
2logOnly
3softReset
4hardReset
.1.3.6.1.4.1.664.5.73.2.1.1.1.6