ADTRAN-GEMINAX-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
1
Rows
1
Columns
6
adGenGeminaxDiagTable
table.1.3.6.1.4.1.664.5.73.2.1.1
·
1 row entry
·
6 columns
This table contains information on the Lantiq (Infineon) GeminaxMax DSP. Each entry reflects a required parameter or action required to perform either the SELT or DELT diagnostic test.
This table contains configuration parameters for the GeminaxMax DSP.
The entries are used to configure the recovery option settings.
The entries are used to configure the recovery option settings.
Indexes
ADTRAN-GENSLOT-MIBadGenSlotInfoIndex
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
adGenGeminaxErrorClassECF
Sets the action to be taken when a Class ECF error occurs. The following settings are allowed:
disabled(1) - do nothing, logOnly(2) - log the event, softReset(3) - trigger a soft reset, hardReset(4) - trigger a hard res… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.664.5.73.2.1.1.1.1 |
||||||||
|
adGenGeminaxErrorClassA
Sets the action to be taken when a Class A error occurs. The following settings are allowed:
disabled(1) - do nothing, logOnly(2) - log the event, softReset(3) - trigger a soft reset, hardReset(4) - trigger a hard reset |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.664.5.73.2.1.1.1.2 |
||||||||
|
adGenGeminaxErrorClassB
Sets the action to be taken when a Class B error occurs. The following settings are allowed:
disabled(1) - do nothing, logOnly(2) - log the event, softReset(3) - trigger a soft reset, hardReset(4) - trigger a hard reset |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.664.5.73.2.1.1.1.3 |
||||||||
|
adGenGeminaxErrorClassC
Sets the action to be taken when a Class C error occurs. The following settings are allowed:
disabled(1) - do nothing, logOnly(2) - log the event, softReset(3) - trigger a soft reset, hardReset(4) - trigger a hard reset |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.664.5.73.2.1.1.1.4 |
||||||||
|
adGenGeminaxErrorClassD
Sets the action to be taken when a Class D error occurs. The following settings are allowed:
disabled(1) - do nothing, logOnly(2) - log the event, softReset(3) - trigger a soft reset, hardReset(4) - trigger a hard reset |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.664.5.73.2.1.1.1.5 |
||||||||
|
adGenGeminaxErrorClassE
Sets the action to be taken when a Class E error occurs. The following settings are allowed:
disabled(1) - do nothing, logOnly(2) - log the event, softReset(3) - trigger a soft reset, hardReset(4) - trigger a hard reset |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.664.5.73.2.1.1.1.6 |