stackConfigTable

table mandatory
.1.3.6.1.4.1.43.10.27.1.1 · 1 row entry · 17 columns
stackConfigEntry entry .1.3.6.1.4.1.43.10.27.1.1.1
Indexes
stackUnitLocation
Column Syntax OID
stackUnitLocation mandatory
Used to identify individual units in the stack. Note that
this value will usually be contiguous, but that gaps may be present due,
for example, to unpowered units.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.43.10.27.1.1.1.1
stackUnitAddress mandatory
Every conformant unit in the SuperStack II system will have
a unique physical (MAC) address by which it can be recognised. Note
that the location index on this table can change if a unit is inserted
into the stack an…
RFC1213-MIBPhysAddress
Textual Convention: RFC1213-MIBPhysAddress OctetString
.1.3.6.1.4.1.43.10.27.1.1.1.2
stackUnitLastReset mandatory
This is the time in hundredths of a second, since this unit
last reset (ie that units concept of sysUpTime). Note that if a unit is
not operational then this object will report zero (0).
RFC1155-SMITimeTicks
Textual Convention: RFC1155-SMITimeTicks Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.43.10.27.1.1.1.3
stackUnitType mandatory
This is an integer type identifier for this unit. The values
of this integer are administered by allocating a MIB object identifier
for each type of unit from a common branch. The value of this object is
then the las…
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.43.10.27.1.1.1.4
stackUnitDesc mandatory
This is a text string which describes this unit. If a unit
cannot provide a name then the value of this object will be an empty
string.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.43.10.27.1.1.1.5
stackUnitName mandatory
This is a simple text string which can be used by an
application to assign a text name to a unit. By default this string is
empty. If a management application writes a text string to this object
the device will store…
OctetStringr/w
Constraints:
range: 0-30
.1.3.6.1.4.1.43.10.27.1.1.1.6
stackUnitState mandatory
This object represents the best known state of a unit in the
stack. The unknown state is not expected to be used, but may exist
because of loosely integrated components in the stack. Management
applications MUST EXPE…
Enumeration
Enumerated Values:
1unitStateUnknown
2unitInactive
3unitOperational
4unitLoading
.1.3.6.1.4.1.43.10.27.1.1.1.7
stackUnitManagementType mandatory
This object can be used to determine the management method
used to access the agent in this unit. The options are:

unknown: The unit has not reported any management capability. It
i…
Enumeration
Enumerated Values:
1unknown
2distributed
3intelligent
.1.3.6.1.4.1.43.10.27.1.1.1.8
stackUnitCapabilities mandatory
This object describes the capabilities of this particular
unit. This is used in conjunction with the upgrade level of the stack
to enable a management application to correctly enable and disable the
various features …
OctetString .1.3.6.1.4.1.43.10.27.1.1.1.9
stackUnitPromVersion mandatory
This is the version number of the PROM on the unit. If the
unit has no PROM, does not correctly report the PROM version or is
currently non-operational then this object will return an empty string.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.43.10.27.1.1.1.10
stackUnitHWVersion mandatory
This is the hardware version of this unit, expressed as a
string. Note that if the hardware version is not available for this
particular unit then the version string will be empty.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.43.10.27.1.1.1.11
stackUnitSWVersion mandatory
This is the software version number of this unit. The
software version number is a string. Note that if a unit does not make
its version number information available, or the unit has no software,
then this object wil…
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.43.10.27.1.1.1.12
stackUnitSerialNumber mandatory
This is the serial number for this unit. The number is
globally unique and expressed as a textual string.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.43.10.27.1.1.1.13
stackUnitAttention mandatory
Some of the units in the stack will contain a mechanism for
drawing attention to that unit. This is useful for directing
maintainance personnel. The method often employed is for a special LED,
or by placing some othe…
Enumerationr/w
Enumerated Values:
1noAttention
2attention
.1.3.6.1.4.1.43.10.27.1.1.1.14
stackUnitMgmtInterface mandatory
If a unit in the stack participates in the distributed
SNMP stack then it will have an instance of this object
(stackUnitManagementType = 'distributed'). The object points to the
entry in the interface table which repre…
Integer32
Constraints:
range: 0-65535
.1.3.6.1.4.1.43.10.27.1.1.1.15
stackUnitSummary mandatory
This object provides a summary of this units configuration
in order to improve the performance of the management applications. The
information in this object is represented as a list of items, each item
is a type-len…
OctetString .1.3.6.1.4.1.43.10.27.1.1.1.16
stackUnitSlipMgmtInterface mandatory
If a unit in the stack participates in the distributed
SNMP stack then it will have an instance of this object
(stackUnitManagementType = 'distributed'). The object points to the
entry in the interface table which repre…
Integer32
Constraints:
range: 0-65535
.1.3.6.1.4.1.43.10.27.1.1.1.17

stackAddressTable

table mandatory
.1.3.6.1.4.1.43.10.27.2.1 · 1 row entry · 3 columns
This table contains entries for units in the stack which 
have active inband communications stacks. The table comprises of a set 
of entries for each unit, each entry representing a single address. 
Note that the address information in this table cannot be changed!
          
This table is required specifically for those units which execute their 
own SNMP agents without taking part in the Arnie co-operative agent. Ie,
 the only devices for which there will be an entry in this table are 
those for which the stackUnitManagementType is 'Intelligent'.
stackAddressEntry entry .1.3.6.1.4.1.43.10.27.2.1.1
Indexes
stackUnitLocation stackAddressNumber
Column Syntax OID
stackAddressNumber mandatory
This identifies one of a number of different addresses for
this unit. This is a second index column for this table, the first
being the unit number shared with the stackConfigTable (stackUnitLocatio
n).
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.43.10.27.2.1.1.1
stackAddressType mandatory Enumerationr/w
Enumerated Values:
1ipAddress
2ipxAddress
.1.3.6.1.4.1.43.10.27.2.1.1.2
stackAddress mandatory
The address.