A3COM0017-STACK-CONFIG Table View
Table-centric layout grouping table, row, and column objects.
Tables
2
Rows
2
Columns
20
.1.3.6.1.4.1.43.10.27.1.1
·
1 row entry
·
17 columns
Indexes
stackUnitLocation
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
stackUnitLocation
mandatory
Used to identify individual units in the stack. Note that
this value will usually be contiguous, but that gaps may be present due, for example, to unpowered units. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.43.10.27.1.1.1.1 |
||||||||
|
stackUnitAddress
mandatory
Every conformant unit in the SuperStack II system will have
a unique physical (MAC) address by which it can be recognised. Note that the location index on this table can change if a unit is inserted into the stack an… |
RFC1213-MIBPhysAddress Textual Convention: RFC1213-MIBPhysAddress OctetString |
.1.3.6.1.4.1.43.10.27.1.1.1.2 |
||||||||
|
stackUnitLastReset
mandatory
This is the time in hundredths of a second, since this unit
last reset (ie that units concept of sysUpTime). Note that if a unit is not operational then this object will report zero (0). |
RFC1155-SMITimeTicks Textual Convention: RFC1155-SMITimeTicks Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.43.10.27.1.1.1.3 |
||||||||
|
stackUnitType
mandatory
This is an integer type identifier for this unit. The values
of this integer are administered by allocating a MIB object identifier for each type of unit from a common branch. The value of this object is then the las… |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.43.10.27.1.1.1.4 |
||||||||
|
stackUnitDesc
mandatory
This is a text string which describes this unit. If a unit
cannot provide a name then the value of this object will be an empty string. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.43.10.27.1.1.1.5 |
||||||||
|
stackUnitName
mandatory
This is a simple text string which can be used by an
application to assign a text name to a unit. By default this string is empty. If a management application writes a text string to this object the device will store… |
OctetStringr/w Constraints: range: 0-30 |
.1.3.6.1.4.1.43.10.27.1.1.1.6 |
||||||||
|
stackUnitState
mandatory
This object represents the best known state of a unit in the
stack. The unknown state is not expected to be used, but may exist because of loosely integrated components in the stack. Management applications MUST EXPE… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.43.10.27.1.1.1.7 |
||||||||
|
stackUnitManagementType
mandatory
This object can be used to determine the management method
used to access the agent in this unit. The options are: unknown: The unit has not reported any management capability. It i… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.43.10.27.1.1.1.8 |
||||||||
|
stackUnitCapabilities
mandatory
This object describes the capabilities of this particular
unit. This is used in conjunction with the upgrade level of the stack to enable a management application to correctly enable and disable the various features … |
OctetString | .1.3.6.1.4.1.43.10.27.1.1.1.9 |
||||||||
|
stackUnitPromVersion
mandatory
This is the version number of the PROM on the unit. If the
unit has no PROM, does not correctly report the PROM version or is currently non-operational then this object will return an empty string. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.43.10.27.1.1.1.10 |
||||||||
|
stackUnitHWVersion
mandatory
This is the hardware version of this unit, expressed as a
string. Note that if the hardware version is not available for this particular unit then the version string will be empty. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.43.10.27.1.1.1.11 |
||||||||
|
stackUnitSWVersion
mandatory
This is the software version number of this unit. The
software version number is a string. Note that if a unit does not make its version number information available, or the unit has no software, then this object wil… |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.43.10.27.1.1.1.12 |
||||||||
|
stackUnitSerialNumber
mandatory
This is the serial number for this unit. The number is
globally unique and expressed as a textual string. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.43.10.27.1.1.1.13 |
||||||||
|
stackUnitAttention
mandatory
Some of the units in the stack will contain a mechanism for
drawing attention to that unit. This is useful for directing maintainance personnel. The method often employed is for a special LED, or by placing some othe… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.43.10.27.1.1.1.14 |
||||||||
|
stackUnitMgmtInterface
mandatory
If a unit in the stack participates in the distributed
SNMP stack then it will have an instance of this object (stackUnitManagementType = 'distributed'). The object points to the entry in the interface table which repre… |
Integer32 Constraints: range: 0-65535 |
.1.3.6.1.4.1.43.10.27.1.1.1.15 |
||||||||
|
stackUnitSummary
mandatory
This object provides a summary of this units configuration
in order to improve the performance of the management applications. The information in this object is represented as a list of items, each item is a type-len… |
OctetString | .1.3.6.1.4.1.43.10.27.1.1.1.16 |
||||||||
|
stackUnitSlipMgmtInterface
mandatory
If a unit in the stack participates in the distributed
SNMP stack then it will have an instance of this object (stackUnitManagementType = 'distributed'). The object points to the entry in the interface table which repre… |
Integer32 Constraints: range: 0-65535 |
.1.3.6.1.4.1.43.10.27.1.1.1.17 |
.1.3.6.1.4.1.43.10.27.2.1
·
1 row entry
·
3 columns
This table contains entries for units in the stack which
have active inband communications stacks. The table comprises of a set
of entries for each unit, each entry representing a single address.
Note that the address information in this table cannot be changed!
This table is required specifically for those units which execute their
own SNMP agents without taking part in the Arnie co-operative agent. Ie,
the only devices for which there will be an entry in this table are
those for which the stackUnitManagementType is 'Intelligent'.
Indexes
stackUnitLocation stackAddressNumber
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
stackAddressNumber
mandatory
This identifies one of a number of different addresses for
this unit. This is a second index column for this table, the first being the unit number shared with the stackConfigTable (stackUnitLocatio n). |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.43.10.27.2.1.1.1 |
||||
| stackAddressType mandatory | Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.43.10.27.2.1.1.2 |
||||
|
stackAddress
mandatory
The address.
|
OctetStringr/w | .1.3.6.1.4.1.43.10.27.2.1.1.3 |