sfpConfigLengthCopper1m

SL-SFP-MIB · smartoptics variant · .1.3.6.1.4.1.4515.1.10.1.1.1.17

Object

This value specifies the link length that is supported by the transceiver 
while operating in compliance with the applicable standards using copper cable. 
The value is in units of 1 meter. A value of 255 means that the transceiver 
supports a link length greater than 254 meters.
A value of zero means that the transceiver does not support copper cables 
or that the length information must be determined from the 
transceiver technology.

Context

MIB
SL-SFP-MIB
OID
.1.3.6.1.4.1.4515.1.10.1.1.1.17
Type
column
Access
readonly
Status
current
Parent
sfpConfigEntry

Walk the column to discover its indexed instances, or supply every index to read one instance.

Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SL-SFP-MIB' -M '/opt/observium/mibs/smartoptics:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SL-SFP-MIB::sfpConfigLengthCopper1m'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'SL-SFP-MIB' -M '/opt/observium/mibs/smartoptics:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SL-SFP-MIB::sfpConfigLengthCopper1m.<sfpConfigInterface>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'SL-SFP-MIB' -M '/opt/observium/mibs/smartoptics:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'SL-SFP-MIB::sfpConfigLengthCopper1m'

Syntax

Source
SNMPv2-SMIInteger32
Base type
Integer32

Values & Constraints

Type Constraints
range: -2147483648..2147483647