imaGroupTestLinkIfIndex

IMA-MIB · huawei variant · .1.3.6.1.4.1.353.5.7.1.1.2.1.35

Object

This object is used to designate an interface as the test link
for use in the Test Pattern Procedure.  The distinguished value of
zero specifies that the implementation may choose the Test Link,
in which case, the implementation may also choose the value of
'imaGroupTestPattern'.  The value zero may also be used if no link
has yet been added to the group.
              
Note that this value is NOT the same as the Tx LID value, but
instead either identifies the ifIndex value of the test link to be
used by the Test Pattern Procedure (i.e., the link whose LID value
is inserted in the Tx LID field of the transmitted ICP cells),
or identifies that the implementation may choose the test link (if
the value is zero).

Context

MIB
IMA-MIB
OID
.1.3.6.1.4.1.353.5.7.1.1.2.1.35
Type
column
Access
readwrite
Status
current
Parent
imaGroupEntry
Groups
1

Walk the column to discover its indexed instances, or supply every index to read one instance.

Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'IMA-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'IMA-MIB::imaGroupTestLinkIfIndex'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'IMA-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'IMA-MIB::imaGroupTestLinkIfIndex.<imaGroupIndex>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'IMA-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'IMA-MIB::imaGroupTestLinkIfIndex'

Syntax

Source
IF-MIBInterfaceIndexOrZero
Base type
Integer32
Display format
d
Type Description
This textual convention is an extension of the
InterfaceIndex convention.  The latter defines a greater
than zero value used to identify an interface or interface
sub-layer in the managed system.  This extension permits the
additional value of zero.  the value zero is object-specific
and must therefore be defined as part of the description of
any object which uses this syntax.  Examples of the usage of
zero might include situations where interface was unknown,
or when none or all interfaces need to be referenced.

Values & Constraints

Type Constraints
range: 0..2147483647

Conformance

Member of
Compliance refinements
Write access is not required.