igControlChannelT396
ZhoneGR303-MIB ·
.1.3.6.1.4.1.5504.4.3.1.2.1.4
Object
column
r/w
milliseconds Integer32
Value of the T396 timer for the Q931 protocol.
12.5.5.17.9 T396
T396 is the length of time that the RDT will
wait for a reply to a SETUP message following
the initial expiration of timer T303.
R12-459 [1328] The value of T396 shall be
provisionable from 700 ms through 14.7 seconds
in steps of 1 second; the default shall be 14.7
seconds.
R12-460 [1329] The above range is not intended
to define acceptable response-time performance
at the IDT, where the low-load (i.e., no other
external stimuli requiring call processing
activity) mean response time to a SETUP message
shall be no greater than 500 ms.
Units in milliseconds.
Context
- MIB
- ZhoneGR303-MIB
- OID
.1.3.6.1.4.1.5504.4.3.1.2.1.4- Type
- column
- Access
- readwrite
- Status
- current
- Units
- milliseconds
- Parent
- igControlChannelEntry
Syntax
milliseconds Integer32
Values & Constraints
No enumerated values or constraints recorded.