igControlChannelT303
ZhoneGR303-MIB ·
.1.3.6.1.4.1.5504.4.3.1.2.1.3
Object
column
r/w
milliseconds Integer32
Value of the T303 timer for the Q931 protocol
12.5.5.17.1 T303
T303 is the length of time that the IDT and RDT
will wait for a reply to a SETUP message.
R12-446 [1315] At the IDT, the value of T303 is
not user settable, its value depends on specific
vendor implementations, but shall be within the
range of 700 ms to 4 seconds.
R12-447 [1316] The above range is not intended to
define acceptable response-time performance at
the RDT, where the low-load (i.e., no other
external stimuli requiring call processing
activity) mean response time to a SETUP message
shall be no greater than 200 ms.
R12-448 [1317] At the RDT, the value of T303
shall be provisionable from 700 ms through 4.7
seconds in steps of 500 ms; the default shall be
700 ms.
R12-449 [1318] The above range is not intended
to define acceptable response-time performance
at the IDT, where the low-load (i.e., no other
external stimuli requiring call processing
activity) mean response time to a SETUP message
shall be no greater than 500 ms.
Units in milliseconds.
Context
- MIB
- ZhoneGR303-MIB
- OID
.1.3.6.1.4.1.5504.4.3.1.2.1.3- Type
- column
- Access
- readwrite
- Status
- current
- Units
- milliseconds
- Parent
- igControlChannelEntry
Syntax
milliseconds Integer32
Values & Constraints
No enumerated values or constraints recorded.