zyMstpGeneralMaxAge

ZYXEL-MSTP-MIB · .1.3.6.1.4.1.890.1.15.3.53.1.1.5

Object

scalar r/w Integer32
This is the maximum time (in seconds) the switch can wait 
without receiving a BPDU before attempting to reconfigure

Context

MIB
ZYXEL-MSTP-MIB
OID
.1.3.6.1.4.1.890.1.15.3.53.1.1.5
Type
scalar
Access
readwrite
Status
current
Parent
zyxelMstpGeneral

Scalars have one instance, identified by the .0 suffix.

Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'ZYXEL-MSTP-MIB' -M '/opt/observium/mibs/zyxel:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ZYXEL-MSTP-MIB::zyMstpGeneralMaxAge.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'ZYXEL-MSTP-MIB' -M '/opt/observium/mibs/zyxel:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'ZYXEL-MSTP-MIB::zyMstpGeneralMaxAge'

Syntax

Integer32

Values & Constraints

No enumerated values or constraints recorded.