pingCtlFrequency
ZYXEL-ES3124PWR-MIB ·
.1.3.6.1.4.1.890.1.5.8.14.23.2.1.12
Object
column
r/w
seconds Unsigned32
The number of seconds to wait before repeating a ping test as defined by the value of the various objects in the corresponding row. A single ping test consists of a series of ping probes. The number of probes is determined by the value of the corresponding pingCtlProbeCount object. After a single test completes the number of seconds as defined by the value of pingCtlFrequency MUST elapse before the next ping test is started. A value of 0 for this object implies that the test as defined by the corresponding entry will not be repeated.
Context
- MIB
- ZYXEL-ES3124PWR-MIB
- OID
.1.3.6.1.4.1.890.1.5.8.14.23.2.1.12- Type
- column
- Access
- readwrite
- Status
- current
- Units
- seconds
- Parent
- pingCtlEntry
Syntax
seconds Unsigned32
Values & Constraints