dot3OamErrFrameWindow
ZXEPON-SERVICE-OAM-MIB ·
.1.3.6.1.4.1.3902.1015.1010.1.6.5.1.9
Object
column
r/w
tenths of a second Unsigned32
The amount of time (in 100ms increments) over which the threshold is defined. The default value is 10 (1 second). If OamErrFrameThreshold frame errors occur within a window of OamErrFrameWindow seconds (measured in tenths of seconds), an Event Notification OAMPDU should be generated with an Errored Frame Event TLV indicating the threshold has been crossed in this window.
Context
- MIB
- ZXEPON-SERVICE-OAM-MIB
- OID
.1.3.6.1.4.1.3902.1015.1010.1.6.5.1.9- Type
- column
- Access
- readwrite
- Status
- current
- Units
- tenths of a second
- Parent
- dot3OamEventConfigEntry
Syntax
tenths of a second Unsigned32
Values & Constraints
No enumerated values or constraints recorded.