dot3OamErrFrameWindow

ZXEPON-SERVICE-OAM-MIB · .1.3.6.1.4.1.3902.1015.1010.1.6.5.1.9

Object

column r/w tenths of a second Unsigned32
The amount of time (in 100ms increments) over which the threshold is defined. 
The default value is 10 (1 second). If OamErrFrameThreshold frame errors occur 
within a window of OamErrFrameWindow seconds (measured in tenths of seconds), 
an Event Notification OAMPDU should be generated with an Errored Frame Event TLV 
indicating the threshold has been crossed in this window.

Context

MIB
ZXEPON-SERVICE-OAM-MIB
OID
.1.3.6.1.4.1.3902.1015.1010.1.6.5.1.9
Type
column
Access
readwrite
Status
current
Units
tenths of a second
Parent
dot3OamEventConfigEntry

Syntax

tenths of a second Unsigned32

Values & Constraints

No enumerated values or constraints recorded.