zxAnOpticalRxPwrLowerThresh
ZTE-AN-OPTICAL-MODULE-MIB ·
.1.3.6.1.4.1.3902.1082.30.40.2.2.1.2
Object
column r/w
0.1dBmInteger32
The lower limit threshold on input optical power. The alarm should be generated when zxAnOpticalIfRxPwrCurrValue is lower than this threshold. The unit is 0.1dBm when the value of opticalModuleAlarmImprovement(3) is 1, otherwise the unit is 1dBm when the value of opticalAlarmPrfUnit(1) is 1 and the unit is 0.1dBm when the value of opticalAlarmPrfUnit(1) is 0. The default value is -330 and syntax is Integer32(-400..100) when the value of opticalModuleAlarmImprovement(3) is 1, otherwise the default value is -20 and syntax is Integer32.
Context
- MIB
- ZTE-AN-OPTICAL-MODULE-MIB
- OID
.1.3.6.1.4.1.3902.1082.30.40.2.2.1.2- Type
- column
- Access
- readwrite
- Status
- current
- Units
- 0.1dBm
- Default
-330- Parent
- zxAnOpticalModuleAlmPrfEntry
Net-SNMP examples
How SNMP and these commands workWalk the column to discover its indexed instances, or supply every index to read one instance.
Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ZTE-AN-OPTICAL-MODULE-MIB' -M '/opt/observium/mibs/zte-ng:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ZTE-AN-OPTICAL-MODULE-MIB::zxAnOpticalRxPwrLowerThresh'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'ZTE-AN-OPTICAL-MODULE-MIB' -M '/opt/observium/mibs/zte-ng:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ZTE-AN-OPTICAL-MODULE-MIB::zxAnOpticalRxPwrLowerThresh.<zxAnOpticalModuleAlmPrfName>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'ZTE-AN-OPTICAL-MODULE-MIB' -M '/opt/observium/mibs/zte-ng:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'ZTE-AN-OPTICAL-MODULE-MIB::zxAnOpticalRxPwrLowerThresh'
Syntax
0.1dBmInteger32
Values & Constraints
Object Constraints
range: -400-100