zxAnClockSrcSwitchNewInfo
ZTE-AN-CLOCK-MIB ·
.1.3.6.1.4.1.3902.1082.120.10.1.11
Object
scalar SNMPv2-SMIInteger32
the active clock source identify after switch: |shelf| slot | port |clockType| 0000 0000 0000 0000 0000 0000 0000 0000 clockType: 0: internal clock 2: external clock 3: E1 clock not supported this version 6: synchronous ethernet equipment clock 7: SDH clock not supported this version 8: PTP clock not supported this version
Context
- MIB
- ZTE-AN-CLOCK-MIB
- OID
.1.3.6.1.4.1.3902.1082.120.10.1.11- Type
- scalar
- Access
- readonly
- Status
- current
- Parent
- zxAnClockGlobalObjects
- Groups
- 1
Net-SNMP examples
How SNMP and these commands workScalars have one instance, identified by the .0 suffix.
Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'ZTE-AN-CLOCK-MIB' -M '/opt/observium/mibs/zte-ng:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ZTE-AN-CLOCK-MIB::zxAnClockSrcSwitchNewInfo.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'ZTE-AN-CLOCK-MIB' -M '/opt/observium/mibs/zte-ng:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'ZTE-AN-CLOCK-MIB::zxAnClockSrcSwitchNewInfo'
Syntax
- Source
- SNMPv2-SMIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Conformance
Member of