zhonePrimaryClockSource

ZHONE-SYSTEM-MIB · .1.3.6.1.4.1.5504.3.1.5.8

Object

scalar deprecated r/w IF-MIBInterfaceIndexOrZero
The ifIndex of the interface from which clock can be derived.
Only oc3, ds1, and ds3 interfaces can be used for this.
                                          
This interface will be used to drive the 8khz backplane
signal.
                                          
The interface must be set to loop or local timing in order for
it to be considered as the primary clock source.  It must
also be administratively turned on and be in an operational state.
                                          
Only one interface in the system can be the primary clock source
at any given time.
                                          
                                          
NOTE: This value has been deprecated and should not be used. If
specified, the system will use this interface as the clock source
and will ignore the provisioning specified in the
zhoneSystemClockTable.

Context

MIB
ZHONE-SYSTEM-MIB
OID
.1.3.6.1.4.1.5504.3.1.5.8
Type
scalar
Access
readwrite
Status
deprecated
Parent
zhoneSystemConfiguration
Groups
1

Scalars have one instance, identified by the .0 suffix.

Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'ZHONE-SYSTEM-MIB' -M '/opt/observium/mibs/zhone:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ZHONE-SYSTEM-MIB::zhonePrimaryClockSource.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'ZHONE-SYSTEM-MIB' -M '/opt/observium/mibs/zhone:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'ZHONE-SYSTEM-MIB::zhonePrimaryClockSource'

Syntax

Source
IF-MIBInterfaceIndexOrZero
Base type
Integer32
Display format
d
Type Description
This textual convention is an extension of the
InterfaceIndex convention.  The latter defines a greater
than zero value used to identify an interface or interface
sub-layer in the managed system.  This extension permits the
additional value of zero.  the value zero is object-specific
and must therefore be defined as part of the description of
any object which uses this syntax.  Examples of the usage of
zero might include situations where interface was unknown,
or when none or all interfaces need to be referenced.

Values & Constraints

Type Constraints
range: 0..2147483647

Conformance