sysTransmitClockSource
ZHNSYSTEM ·
.1.3.6.1.4.1.5504.2.5.2.1.1.11
Object
T1 Clock source for PWE device. Since both T1/E1 interfaces will be required to have the same source, this object will replace the dsx1TransmitClockSource object in the DS1-MIB. This object is not supported by ZNID devices.
Context
- MIB
- ZHNSYSTEM
- OID
.1.3.6.1.4.1.5504.2.5.2.1.1.11- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- zhnSystemGeneralObjects
- Groups
- 1
Net-SNMP examples
How SNMP and these commands workScalars have one instance, identified by the .0 suffix.
Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'ZHNSYSTEM' -M '/opt/observium/mibs/zhone:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ZHNSYSTEM::sysTransmitClockSource.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'ZHNSYSTEM' -M '/opt/observium/mibs/zhone:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'ZHNSYSTEM::sysTransmitClockSource'
Values & Constraints
Type Values
0 | notApplicable |
1 | loop |
2 | local |
3 | pwe |
Conformance
Member of