powerSheddingAdminStatus

ZHNSYSTEM · .1.3.6.1.4.1.5504.2.5.2.1.12.1

Object

Configuration of parameters for the power-shedding feature.
The power-shedding objects are only supported by systems that 
include on-board power-management circuitry. When the system 
detects that it is running on battery power, it has the option 
to shut down all support (excluding the voice over IP telephone 
service).The power-shedding administrative state will enable 
or disable the power-shedding feature.

Context

MIB
ZHNSYSTEM
OID
.1.3.6.1.4.1.5504.2.5.2.1.12.1
Type
scalar
Access
readonly
Status
current
Parent
zhnSystemPowerSheddingObjects
Groups
1

Scalars have one instance, identified by the .0 suffix.

Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'ZHNSYSTEM' -M '/opt/observium/mibs/zhone:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ZHNSYSTEM::powerSheddingAdminStatus.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'ZHNSYSTEM' -M '/opt/observium/mibs/zhone:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'ZHNSYSTEM::powerSheddingAdminStatus'

Syntax

Source
SysAdminStatus
Base type
Enumeration

Values & Constraints

Type Values
1enable
2disable

Conformance