xdcDisableMode
XDC330X-MIB ·
.1.3.6.1.4.1.13827.16.2.4
Object
scalar SNMPv2-TCDisplayString
Current DisableMode settings as returned by the CLI disablemode command.
It consists of three comma-separated sub-strings. From left to right,
the first string is either Y or N to indicate whether the Disable A input
is to be used for input switching or to be ignored, respectively. The
second string is either Y or N to indicate whether the Disable B input is
to be used for input switching or to be ignored, respectively.
The third string is either ON or OFF and is only meaningful if either of the
two Disable inputs are enabled for switching. It indicates whether the
secondary input, following a failure of the primary input, will be left ON
or switched OFF if the secondary Disable input is subsequently asserted.
In some systems, it might be desirable to allow the secondary input to continue
to drive the downstream equipment rather than completely shut off the
signal.
Context
- MIB
- XDC330X-MIB
- OID
.1.3.6.1.4.1.13827.16.2.4- Type
- scalar
- Access
- readonly
- Status
- current
- Parent
- xdc
Net-SNMP examples
How SNMP and these commands workScalars have one instance, identified by the .0 suffix.
Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'XDC330X-MIB' -M '/opt/observium/mibs/endrun:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'XDC330X-MIB::xdcDisableMode.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'XDC330X-MIB' -M '/opt/observium/mibs/endrun:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'XDC330X-MIB::xdcDisableMode'
Syntax
- Source
- SNMPv2-TCDisplayString
- Base type
OctetString- Display format
255a
Type Description
Represents textual information taken from the NVT ASCII
character set, as defined in pages 4, 10-11 of RFC 854.
To summarize RFC 854, the NVT ASCII repertoire specifies:
- the use of character codes 0-127 (decimal)
- the graphics characters (32-126) are interpreted as
US ASCII
- NUL, LF, CR, BEL, BS, HT, VT and FF have the special
meanings specified in RFC 854
- the other 25 codes have no standard interpretation
- the sequence 'CR LF' means newline
- the sequence 'CR NUL' means carriage-return
- an 'LF' not preceded by a 'CR' means moving to the
same column on the next line.
- the sequence 'CR x' for any x other than LF or NUL is
illegal. (Note that this also means that a string may
end with either 'CR LF' or 'CR NUL', but not with CR.)
Any object defined using this syntax may not exceed 255
characters in length.
Values & Constraints
Object Constraints
range: 0-7
Type Constraints
range: 0..255