wwpPhyModRebootOperation
WWP-PHYSICAL-MODULE-MIB ·
.1.3.6.1.4.1.6141.2.3.1.2.1
Object
scalar
r/w
Enumeration
Writing one of the specified values to this field causes
the specified type of reboot to occur.
none is the value returned when this leaf is queried.
writing this value to the leaf will have no effect.
reboot causes the sytsem to reboot and restart using
its current configuration.
rebootReinit causes the module to remove all its
configuration and application files and get new
files and configuration via bootp/dhcp.
rebootDefault will reset the system to factory defaults.
If the system doesn't support any of these reboot option, it should
return error while trying to set this object to
specific option.
Context
- MIB
- WWP-PHYSICAL-MODULE-MIB
- OID
.1.3.6.1.4.1.6141.2.3.1.2.1- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- wwpPhyModuleRebootAttr
- Siblings
- 2
Syntax
Enumeration
Values & Constraints
Enumerated Values
0 | none |
1 | reboot |
2 | rebootReinit |
3 | rebootDefault |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| wwpPhyModLastRebootTime Indicates the date and time the module last rebooted itself. | scalar | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.6141.2.3.1.2.2 |
| wwpPhyModLastRebootReason Indicates the reason for the last reboot. | scalar | Enumeration | .1.3.6.1.4.1.6141.2.3.1.2.3 |