wwpOamEventLogOui
WWP-OAM-MIB ·
.1.3.6.1.4.1.6141.2.400.1.2.7.1.4
Object
column
OctetString
The OUI of the entity defining the object type. All IEEE 802.3 defined events (as appearing in [802.3ah] except for the Organizationally Unique Event TLVs) use the IEEE 802.3 OUI of 0x0180C2. Organizations defining their own Event Notification TLVs include their OUI in the Event Notification TLV which gets reflected here.
Context
- MIB
- WWP-OAM-MIB
- OID
.1.3.6.1.4.1.6141.2.400.1.2.7.1.4- Type
- column
- Access
- readonly
- Status
- current
- Parent
- wwpOamEventLogEntry
- Table
- wwpOamEventLogTable
- Siblings
- 12
Syntax
OctetString
Values & Constraints
Object Constraints
range: 3-3
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| wwpOamEventLogPort An Ethernet port on the switch | column | Integer32 | .1.3.6.1.4.1.6141.2.400.1.2.7.1.1 |
| wwpOamEventLogThresholdLo If the event represents a threshold crossing event, the two
objects wwpOamEventThresholdHi and wwpOamEventThresholdLo
form an unsigned 64-bit integer yielding the value that was
… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.6141.2.400.1.2.7.1.10 |
| wwpOamEventLogValue If the event represents a threshold crossing event, this
value indicates the value of the parameter within the given
window that generated this event (e.g. 11, when 11 occurrences… | column | SNMPv2-SMICounter64 | .1.3.6.1.4.1.6141.2.400.1.2.7.1.11 |
| wwpOamEventLogRunningTotal This value respresents the total number of times this
occurence has happened since the last reset (e.g. 3253, when
3253 symbol errors have occurred since the last reset, which
has… | column | SNMPv2-SMICounter64 | .1.3.6.1.4.1.6141.2.400.1.2.7.1.12 |
| wwpOamEventLogEventTotal This value respresents the total number of times one or ore
of these occurences have resulted in an event (e.g. 51 when
3253 symbol errors have occurred since the last reset, whic… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.6141.2.400.1.2.7.1.13 |
| wwpOamEventLogIndex An arbitrary integer for identifiying individual events
within the event log. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.6141.2.400.1.2.7.1.2 |
| wwpOamEventLogTimestamp The value of sysUpTime at the time of the logged event. For
locally generated events, the time of the event can be
accurately retrieved from sysUpTime. For remotely generated
ev… | column | SNMPv2-TCTimeStamp | .1.3.6.1.4.1.6141.2.400.1.2.7.1.3 |
| wwpOamEventLogType The type of event that generated this entry in the event log.
When the OUI is the IEEE 802.3 OUI of 0x0180C2, the following
event types are defined:
erroredSymb… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.6141.2.400.1.2.7.1.5 |
| wwpOamEventLogLocation Whether this event occurred locally, or was received from the
OAM peer via Ethernet OAM. | column | Enumeration | .1.3.6.1.4.1.6141.2.400.1.2.7.1.6 |
| wwpOamEventLogWindowHi If the event represents a threshold crossing event, the two
objects wwpOamEventWindowHi and wwpOamEventWindowLo form an
unsigned 64-bit integer yielding the window over which the
… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.6141.2.400.1.2.7.1.7 |
| wwpOamEventLogWindowLo If the event represents a threshold crossing event, the two
objects wwpOamEventWindowHi and wwpOamEventWindowLo form an
unsigned 64-bit integer yielding the window over which the
… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.6141.2.400.1.2.7.1.8 |
| wwpOamEventLogThresholdHi If the event represents a threshold crossing event, the two
objects wwpOamEventThresholdHi and wwpOamEventThresholdLo
form an unsigned 64-bit integer yielding the value that was
… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.6141.2.400.1.2.7.1.9 |