wwpLeosOamErrFrameWindow

WWP-LEOS-OAM-MIB · .1.3.6.1.4.1.6141.2.60.400.1.2.6.1.5

Object

column r/w tenths of a second Unsigned32
The amount of time (in 100ms increments) over which the
threshold is defined.  The default value is 10 (1 second).  
                              
If wwpLeosOamErrFrameThreshold frame errors occur within a window
of wwpLeosOamErrFrameWindow seconds (measured in tenths of
seconds), an Event Notification OAMPDU should be generated with
an Errored Frame Event TLV indicating the threshold has been
crossed in this window.

Context

MIB
WWP-LEOS-OAM-MIB
OID
.1.3.6.1.4.1.6141.2.60.400.1.2.6.1.5
Type
column
Access
readwrite
Status
current
Units
tenths of a second
Parent
wwpLeosOamEventConfigEntry
Table
wwpLeosOamEventConfigTable
Siblings
11

Syntax

tenths of a second Unsigned32

Values & Constraints

Object Constraints
range: 10-600

Related Objects

Sibling Objects