wwpLeosOamErrFrameSecsSummaryWindow

WWP-LEOS-OAM-MIB · .1.3.6.1.4.1.6141.2.60.400.1.2.6.1.8

Object

column r/w tenths of a second Integer32
The amount of time (in 100ms intervals) over which the
threshold is defined.  The default value is 100 (10 seconds).  
                              
If wwpLeosOamErrFrameSecsSummaryThreshold frame errors occur
within a window of wwpLeosOamErrFrameSecsSummaryWindow (in tenths
of seconds), an Event Notification OAMPDU should be generated
with an Errored Frame Seconds Summary Event TLV indicating the
threshold has been crossed in this window.

Context

MIB
WWP-LEOS-OAM-MIB
OID
.1.3.6.1.4.1.6141.2.60.400.1.2.6.1.8
Type
column
Access
readwrite
Status
current
Units
tenths of a second
Parent
wwpLeosOamEventConfigEntry
Table
wwpLeosOamEventConfigTable
Siblings
11

Syntax

tenths of a second Integer32

Values & Constraints

Object Constraints
range: 100-9000

Related Objects

Sibling Objects