wwpLeosOamErrFrameSecsSummaryThreshold

WWP-LEOS-OAM-MIB · .1.3.6.1.4.1.6141.2.60.400.1.2.6.1.9

Object

column r/w errored frame seconds Integer32
The number of errored frame seconds that must occur for this
event to be triggered.  The default value is one errored frame
second.  
                              
If wwpLeosOamErrFrameSecsSummaryThreshold frame errors occur
within a window of wwpLeosOamErrFrameSecsSummaryWindow (in tenths
of seconds), an Event Notification OAMPDU should be generated
with an Errored Frame Seconds Summary Event TLV indicating the
threshold has been crossed in this window.

Context

MIB
WWP-LEOS-OAM-MIB
OID
.1.3.6.1.4.1.6141.2.60.400.1.2.6.1.9
Type
column
Access
readwrite
Status
current
Units
errored frame seconds
Parent
wwpLeosOamEventConfigEntry
Table
wwpLeosOamEventConfigTable
Siblings
11

Syntax

errored frame seconds Integer32

Values & Constraints

Object Constraints
range: 0-65535

Related Objects