wwpLeosLldpCounterDiscontinuityTime

WWP-LEOS-LLDP-MIB · .1.3.6.1.4.1.6141.2.60.26.1.2.1.1.9

Object

column deprecated SNMPv2-TCTimeStamp
This object is defined to record the time of the last
discontinuity in statistics counters of the indicated port.
The relevant counters are the specific instances associated
with this port of any Counter32 objects contained in the
wwpLeosLldpStatsTable.  If no such discontinuities have occurred
since the last re-initialization of the local management
subsystem, then this object contains a zero value.

Context

MIB
WWP-LEOS-LLDP-MIB
OID
.1.3.6.1.4.1.6141.2.60.26.1.2.1.1.9
Type
column
Access
readonly
Status
deprecated
Parent
wwpLeosLldpStatsEntry
Groups
1

Walk the column to discover its indexed instances, or supply every index to read one instance.

Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WWP-LEOS-LLDP-MIB' -M '/opt/observium/mibs/ciena:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WWP-LEOS-LLDP-MIB::wwpLeosLldpCounterDiscontinuityTime'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'WWP-LEOS-LLDP-MIB' -M '/opt/observium/mibs/ciena:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WWP-LEOS-LLDP-MIB::wwpLeosLldpCounterDiscontinuityTime.<wwpLeosLldpStatsPortNum>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'WWP-LEOS-LLDP-MIB' -M '/opt/observium/mibs/ciena:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'WWP-LEOS-LLDP-MIB::wwpLeosLldpCounterDiscontinuityTime'

Syntax

Source
SNMPv2-TCTimeStamp
Base type
Unsigned32
Based on
SNMPv2-SMITimeTicks
Type Description
The value of the sysUpTime object at which a specific
occurrence happened.  The specific occurrence must be
          
defined in the description of any object defined using this
type.
          
If sysUpTime is reset to zero as a result of a re-
initialization of the network management (sub)system, then
the values of all TimeStamp objects are also reset.
However, after approximately 497 days without a re-
initialization, the sysUpTime object will reach 2^^32-1 and
then increment around to zero; in this case, existing values
of TimeStamp objects do not change.  This can lead to
ambiguities in the value of TimeStamp objects.

Values & Constraints

No enumerated values or constraints recorded.

Conformance