vmwNsxTTransportNodeHealthTransportNodeUplinkDownOnDPU
VMWARE-NSX-MIB ·
.1.3.6.1.4.1.6876.120.1.0.18.0.11
Object
notification
Uplink on DPU vmwNsxTDataCenterDPUId is going down.
Action required:
Check the physical NICs' status of uplinks on DPU vmwNsxTDataCenterDPUId.
Find out the mapped name of this physical NIC on host, then perform checking on UI.
1. In the NSX UI navigate to Fabric | Nodes | Transport Nodes |
Host Transport Nodes.
2. In the Host Transport Nodes list, check the Node Status column. Find the
Transport node with the degraded or down Node Status.
3. Select <transport node> | Monitor. Check the status details of the
bond(uplink) which is reporting degraded or down. To avoid a degraded state,
ensure all uplink interfaces are connected and up regardless of whether they
are in use or not.
Context
- MIB
- VMWARE-NSX-MIB
- OID
.1.3.6.1.4.1.6876.120.1.0.18.0.11- Type
- notification
- Status
- current
- Parent
- vmwNsxTTransportNodeHealthFeature
- Groups
- 1
Net-SNMP examples
How SNMP and these commands workNotifications are emitted by an agent; they cannot be read with snmpget or walked.
Inspect the notification definition
/usr/bin/snmptranslate -Pud -Ir -Td -m 'VMWARE-NSX-MIB' -M '/opt/observium/mibs/vmware:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'VMWARE-NSX-MIB::vmwNsxTTransportNodeHealthTransportNodeUplinkDownOnDPU'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'VMWARE-NSX-MIB' -M '/opt/observium/mibs/vmware:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'VMWARE-NSX-MIB::vmwNsxTTransportNodeHealthTransportNodeUplinkDownOnDPU'
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Conformance
Member of