vmwNsxTRoutingBGPDown
VMWARE-NSX-MIB ·
.1.3.6.1.4.1.6876.120.1.0.28.0.1
Object
notification
In Router vmwNsxTDataCenterLrId, BGP neighbor vmwNsxTDataCenterEntityId (vmwNsxTDataCenterBGPNeighborIP) is down.
Reason: vmwNsxTDataCenterFailureReason.
Action required:
1. Invoke the NSX CLI command `get logical-routers`.
2. Switch to service-router vmwNsxTDataCenterSrId.
If the reason indicates Network or config error -
3. Invoke the NSX CLI command `get bgp neighbor summary` to check the
BGP neighbor status.
If the reason indicates `Edge is not ready`, check why the Edge node is not in good state.
4. Invoke the NSX CLI command `get edge-cluster status` to check reason why Edge node might be down.
5. Invoke the NSX CLI commands `get bfd-config` and `get bfd-sessions` to check if BFD is running well.
6. Check any Edge health related alarms to get more information.
Check /var/log/syslog to see if there are any errors related to BGP
connectivity.
Context
- MIB
- VMWARE-NSX-MIB
- OID
.1.3.6.1.4.1.6876.120.1.0.28.0.1- Type
- notification
- Status
- current
- Parent
- vmwNsxTRoutingFeature
- Groups
- 1
Net-SNMP examples
How SNMP and these commands workNotifications are emitted by an agent; they cannot be read with snmpget or walked.
Inspect the notification definition
/usr/bin/snmptranslate -Pud -Ir -Td -m 'VMWARE-NSX-MIB' -M '/opt/observium/mibs/vmware:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'VMWARE-NSX-MIB::vmwNsxTRoutingBGPDown'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'VMWARE-NSX-MIB' -M '/opt/observium/mibs/vmware:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'VMWARE-NSX-MIB::vmwNsxTRoutingBGPDown'
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Conformance
Member of