tnPowerMgmtGlobalMaxStepSize

TROPIC-POWERMGMT-MIB · .1.3.6.1.4.1.7483.2.1.6.2.1.1.3

Object

scalar r/w mBSNMPv2-SMIUnsigned32
The maximum change in power per wavelength
permitted over one auto power adjustment
control loop pass.
          
Sets are not supported.

Context

MIB
TROPIC-POWERMGMT-MIB
OID
.1.3.6.1.4.1.7483.2.1.6.2.1.1.3
Type
scalar
Access
readwrite
Status
current
Units
mB
Parent
tnPowerMgmtGlobal
Groups
1

Scalars have one instance, identified by the .0 suffix.

Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'TROPIC-POWERMGMT-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'TROPIC-POWERMGMT-MIB::tnPowerMgmtGlobalMaxStepSize.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'TROPIC-POWERMGMT-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'TROPIC-POWERMGMT-MIB::tnPowerMgmtGlobalMaxStepSize'

Syntax

Source
SNMPv2-SMIUnsigned32
Base type
Unsigned32

Values & Constraints

Type Constraints
range: 0..4294967295

Conformance