tnOthOdukNimDirectionality

TROPIC-OTH-MIB · .1.3.6.1.4.1.7483.2.2.4.10.2.1.6.1.1

Object

column Enumeration
Specifies the monitor point for the ODUk Path
non-intrusive monitoring function.  The value
source(2) is not allowed if the corresponding
instance of tnOthOdukDirectionality has the
value sink(1), and the value sink(1) is not
allowed if the corresponding instance of
tnOthOdukDirectionality has the value source(2).
Either the value sink(1) or source(2) is allowed
if the corresponding instance of
tnOthOdukDirectionality has the value
bidirectional(3).  The value sink(1) means
monitoring at the sink direction path signal of
the ODUk CTP.  The value source(2) means monitoring
at the source direction path signal of the ODUk
CTP.  Monitoring the source direction of an ODUk
CTP is necessary in those cases where the ODUk
CTP is at an SNCP (Subnetwork Connection
Protection) end (e.g., see Figure I.1.2/G.874.1).
If one would like to get the performance of the
protected connection, one cannot use the NIM
function at both ODUk CTP sinks (before the
matrix), instead one should monitor the signal
at the source ODUk CTP after the matrix.

Context

MIB
TROPIC-OTH-MIB
OID
.1.3.6.1.4.1.7483.2.2.4.10.2.1.6.1.1
Type
column
Access
noaccess
Status
current
Parent
tnOthOdukNimEntry
Table
tnOthOdukNimTable
Siblings
12

Syntax

Enumeration

Values & Constraints

Enumerated Values
1sink
2source

Related Objects

Sibling Objects