alarmsDaily
OBS ✓
TRISTAR-MPPT ·
.1.3.6.1.4.1.33333.2.58
Object
scalar AlarmsDailyBitfield
Alarms Daily - Description: Alarms - Modbus addresses: H=0x004b L=0x004c
Observium directly uses this object
This object is referenced by an Observium discovery or polling workflow.
Used in:
Status
Explore Observium network monitoring
Context
- MIB
- TRISTAR-MPPT
- OID
.1.3.6.1.4.1.33333.2.58- Type
- scalar
- Access
- readonly
- Status
- current
- Parent
- tristarmppt
Net-SNMP examples
How SNMP and these commands workScalars have one instance, identified by the .0 suffix.
Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'TRISTAR-MPPT' -M '/opt/observium/mibs/morningstar:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'TRISTAR-MPPT::alarmsDaily.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'TRISTAR-MPPT' -M '/opt/observium/mibs/morningstar:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'TRISTAR-MPPT::alarmsDaily'
Syntax
- Source
- AlarmsDailyBitfield
- Base type
Bits
Values & Constraints
Type Values
0 | rtsOpen |
1 | rtsShorted |
2 | rtsDisconnected |
3 | heatsinkTempSensorOpen |
4 | heatsinkTempSensorShorted |
5 | highTemperatureCurrentLimit |
6 | currentLimit |
7 | currentOffset |
8 | batterySense |
9 | batterySenseDisconnected |
10 | uncalibrated |
11 | rtsMiswire |
12 | highVoltageDisconnect |
13 | undefined |
14 | systemMiswire |
15 | mosfetSOpen |
16 | p12VoltageReferenceOff |
17 | highArrayVCurrentLimit |
18 | maxAdcValueReached |
19 | controllerWasReset |
20 | alarm21Undefined |
21 | alarm22Undefined |
22 | alarm23Undefined |
23 | alarm24Undefined |