faults

TRISTAR-MPPT-600V · .1.3.6.1.4.1.33333.7.55

Object

Faults
- Description: Faults
- Modbus addresses: H=0x002c L=0x002d

Context

MIB
TRISTAR-MPPT-600V
OID
.1.3.6.1.4.1.33333.7.55
Type
scalar
Access
readonly
Status
current
Parent
tristarmppt600v

Scalars have one instance, identified by the .0 suffix.

Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'TRISTAR-MPPT-600V' -M '/opt/observium/mibs/morningstar:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'TRISTAR-MPPT-600V::faults.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'TRISTAR-MPPT-600V' -M '/opt/observium/mibs/morningstar:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'TRISTAR-MPPT-600V::faults'

Syntax

Source
FaultsBitfield
Base type
Bits

Values & Constraints

Type Values
0overcurrent
1fetShort
2softwareFault
3batteryHvd
4arrayHvd
5dipSwitchChange
6customSettingsEdit
7rtsShorted
8rtsDisconnected
9eepromRetryLimit
10controllerWasReset
11chargeSlaveControlTimeout
12rs232SerialToMeterBridge
13batteryLvd
14fault14Undefined
15powerboardCommunicationFault
16fault16Software
17fault17Software
18fault18Software
19fault19Software
20fault20Software
21fault21Software
22fpgaVersion
23currentSensorReferenceOutOfRange
24ia-refSlaveModeTimeout
25blockbusBoot
26hscommMaster
27hscomm
28slave
29fault29Undefined
30fault30Undefined
31fault31Undefined