tn3270eConfSpinLock

TN3270E-MIB · .1.3.6.1.2.1.34.8.1.10

Object

An advisory lock used to allow cooperating
TN3270E-MIB applications to coordinate their use
of the tn3270eSrvrConfTable, the tn3270eSrvrPortTable,
the tn3270eClientGroupTable, the tn3270eResPoolTable,
and the tn3270eClientResMapTable.
          
When creating a new entry or altering an existing entry
in the any of the tables mentioned above, an application
should make use of tn3270eRtSpinLock to serialize
application changes or additions.
          
Since this is an advisory lock, the use of this lock is
not enforced.

Context

MIB
TN3270E-MIB
OID
.1.3.6.1.2.1.34.8.1.10
Type
scalar
Access
readwrite
Status
current
Parent
tn3270eObjects
Groups
1

Scalars have one instance, identified by the .0 suffix.

Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'TN3270E-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'TN3270E-MIB::tn3270eConfSpinLock.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'TN3270E-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'TN3270E-MIB::tn3270eConfSpinLock'

Syntax

Source
SNMPv2-TCTestAndIncr
Base type
Integer32
Type Description
Represents integer-valued information used for atomic
operations.  When the management protocol is used to specify
that an object instance having this syntax is to be
modified, the new value supplied via the management protocol
must precisely match the value presently held by the
instance.  If not, the management protocol set operation
fails with an error of `inconsistentValue'.  Otherwise, if
the current value is the maximum value of 2^31-1 (2147483647
decimal), then the value held by the instance is wrapped to
zero; otherwise, the value held by the instance is
incremented by one.  (Note that regardless of whether the
management protocol set operation succeeds, the variable-
binding in the request and response PDUs are identical.)
          
The value of the ACCESS clause for objects having this
syntax is either `read-write' or `read-create'.  When an
instance of a columnar object having this syntax is created,
any value may be supplied via the management protocol.
          
When the network management portion of the system is re-
initialized, the value of every object instance having this
syntax must either be incremented from its value prior to
the re-initialization, or (if the value prior to the re-
initialization is unknown) be set to a pseudo-randomly
generated value.

Values & Constraints

Type Constraints
range: 0..2147483647

Conformance