sdpKeepAliveMaxDropCount

TN-SDP-MIB · .1.3.6.1.4.1.7483.6.1.2.4.4.3.1.15

Object

column r/w Integer32
This object specifies the maximum number of
consecutive SDP Echo Request messages that can
be unacknowledged before the keep-alive
protocol reports a fault.

Context

MIB
TN-SDP-MIB
OID
.1.3.6.1.4.1.7483.6.1.2.4.4.3.1.15
Type
column
Access
readwrite
Status
current
Parent
sdpInfoEntry

Syntax

Integer32

Values & Constraints

Object Constraints
range: 1-5