sdpBindPwStatusSignaling
TN-SDP-MIB ·
.1.3.6.1.4.1.7483.6.1.2.4.4.4.1.54
Object
The value of sdpBindPwStatusSignaling specified whether this SDP
binding supports pseudowire status signaling.
Default value depends on the type of service:
- For VPLS services it is 'true' and configurable.
- For EPIPE services it is 'true' and configurable.
- For all other VLL services it is 'true' but not configurable.
- For Mirror services it is 'true' but not configurable.
- For IES/VPRN services it is 'true' but not configurable.
- For all other services it is 'false' and not configurable.
An 'inconsistentValue' error is returned when an attempt is made to
change this value for a SDP binding that is not configurable.
Context
- MIB
- TN-SDP-MIB
- OID
.1.3.6.1.4.1.7483.6.1.2.4.4.4.1.54- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- sdpBindEntry
Net-SNMP examples
How SNMP and these commands workWalk the column to discover its indexed instances, or supply every index to read one instance.
Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'TN-SDP-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'TN-SDP-MIB::sdpBindPwStatusSignaling'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'TN-SDP-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'TN-SDP-MIB::sdpBindPwStatusSignaling.<tnSysSwitchId>.<tnSvcId>.<sdpBindId>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'TN-SDP-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'TN-SDP-MIB::sdpBindPwStatusSignaling'
Syntax
- Source
- SNMPv2-TCTruthValue
- Base type
Enumeration
Type Description
Represents a boolean value.
Values & Constraints
Type Values
1 | true |
2 | false |