vRtrNextVRtrID

TIMETRA-VRTR-MIB · .1.3.6.1.4.1.6527.3.1.2.3.15.1

Object

The vRtrNextVRtrID object is used to assign values to vRtrID
to be used to create a new row in the vRtrConfTable as described
in 'Textual Conventions for SNMPv2'.  The network manager reads
the object, and then writes the value back in the SET request
that creates a new instance of vRtrConfEntry.  If the SET fails
with the code 'inconsistentValue', then the process must be
repeated.  If the the SET succeeds, then the object is
incremented and the new instance is created according to the
manager's directions.

Context

MIB
TIMETRA-VRTR-MIB
OID
.1.3.6.1.4.1.6527.3.1.2.3.15.1
Type
scalar
Access
readwrite
Status
current
Parent
tmnxVRtrGlobalObjs
Groups
2

Scalars have one instance, identified by the .0 suffix.

Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'TIMETRA-VRTR-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'TIMETRA-VRTR-MIB::vRtrNextVRtrID.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'TIMETRA-VRTR-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'TIMETRA-VRTR-MIB::vRtrNextVRtrID'

Syntax

Source
SNMPv2-TCTestAndIncr
Base type
Integer32
Type Description
Represents integer-valued information used for atomic
operations.  When the management protocol is used to specify
that an object instance having this syntax is to be
modified, the new value supplied via the management protocol
must precisely match the value presently held by the
instance.  If not, the management protocol set operation
fails with an error of `inconsistentValue'.  Otherwise, if
the current value is the maximum value of 2^31-1 (2147483647
decimal), then the value held by the instance is wrapped to
zero; otherwise, the value held by the instance is
incremented by one.  (Note that regardless of whether the
management protocol set operation succeeds, the variable-
binding in the request and response PDUs are identical.)
          
The value of the ACCESS clause for objects having this
syntax is either `read-write' or `read-create'.  When an
instance of a columnar object having this syntax is created,
any value may be supplied via the management protocol.
          
When the network management portion of the system is re-
initialized, the value of every object instance having this
syntax must either be incremented from its value prior to
the re-initialization, or (if the value prior to the re-
initialization is unknown) be set to a pseudo-randomly
generated value.

Values & Constraints

Type Constraints
range: 0..2147483647