vRtrIfLdpSyncTimer

TIMETRA-VRTR-MIB · .1.3.6.1.4.1.6527.3.1.2.3.4.1.70

Object

column r/w seconds Unsigned32
The value of vRtrIfLdpSyncTimer specifies a time interval used for
IGP-LDP synchronization. The timer is started from the time the LDP
session to the neighbor is up over the interface. This is to allow for
the label FEC bindings to be exchanged.
              
When the timer expires, the link cost is restored and is
re-advertised. IGP will announce a new best next-hop and LDP will use
it if the label binding for the neighbor's FEC is available.

Context

MIB
TIMETRA-VRTR-MIB
OID
.1.3.6.1.4.1.6527.3.1.2.3.4.1.70
Type
column
Access
readwrite
Status
current
Units
seconds
Parent
vRtrIfEntry
Table
vRtrIfTable
Siblings
77

Syntax

seconds Unsigned32

Values & Constraints

Object Constraints
range: 0-1800

Related Objects

Sibling Objects