ssiRedFailoverTime

TIMETRA-SYSTEM-MIB · .1.3.6.1.4.1.6527.3.1.2.1.4.27

Object

The value of ssiRedFailoverTime is the timestamp when the last
redundancy failover occurred causing a switchover from active
to standby CPM.  If there is no redundant CPM card in this system
or no failover has occurred since the system last booted,
ssiRedFailoverTime will always return 0.

Context

MIB
TIMETRA-SYSTEM-MIB
OID
.1.3.6.1.4.1.6527.3.1.2.1.4.27
Type
scalar
Access
readonly
Status
current
Parent
sysSyncInfo
Groups
2

Scalars have one instance, identified by the .0 suffix.

Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'TIMETRA-SYSTEM-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'TIMETRA-SYSTEM-MIB::ssiRedFailoverTime.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'TIMETRA-SYSTEM-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'TIMETRA-SYSTEM-MIB::ssiRedFailoverTime'

Syntax

Source
SNMPv2-TCTimeStamp
Base type
Unsigned32
Based on
SNMPv2-SMITimeTicks
Type Description
The value of the sysUpTime object at which a specific
occurrence happened.  The specific occurrence must be
          
defined in the description of any object defined using this
type.
          
If sysUpTime is reset to zero as a result of a re-
initialization of the network management (sub)system, then
the values of all TimeStamp objects are also reset.
However, after approximately 497 days without a re-
initialization, the sysUpTime object will reach 2^^32-1 and
then increment around to zero; in this case, existing values
of TimeStamp objects do not change.  This can lead to
ambiguities in the value of TimeStamp objects.

Values & Constraints

No enumerated values or constraints recorded.