tmnxPkiCRLExpWarningHours
TIMETRA-SECURITY-MIB ·
.1.3.6.1.4.1.6527.3.1.2.22.18.10
Object
scalar
r/w
hours Integer32
The value of tmnxPkiCRLExpWarningHours specifies the time period (in
hours) at which the system will generate the
tmnxPkiCRLBeforeExpWarning trap for all in-use CRLs (certificate
revocation lists) before expiration. If tmnxPkiCRLExpWarningHours is
configured, the system will also generate the
tmnxPkiCRLAfterExpWarning trap when a CRL expires.
If both tmnxPkiCRLExpWarningHours and tmnxPkiCRLExpWarningRepeatHrs
are configured to 0, the system will only generate the
tmnxPkiCRLAfterExpWarning trap when a CRL expires.
A value of -1 indicates that tmnxPkiCRLExpWarningHours is not
configured. In this case, the system will not generate a trap even
when a CRL expires.
The objects tmnxPkiCRLExpWarningHours and
tmnxPkiCRLExpWarningRepeatHrs have to be set together for the specific
action to be performed.
Context
- MIB
- TIMETRA-SECURITY-MIB
- OID
.1.3.6.1.4.1.6527.3.1.2.22.18.10- Type
- scalar
- Access
- readwrite
- Status
- current
- Units
- hours
- Parent
- tmnxPkiSecurityObjs
Syntax
hours Integer32
Values & Constraints
Object Constraints
range: -1-8760