tmnxIpTunnelReassembly

TIMETRA-SAP-MIB · .1.3.6.1.4.1.6527.3.1.2.4.3.142.1.19

Object

column r/w milliseconds Integer32
The value of tmnxIpTunnelReassembly specifies the maximum number of
seconds to wait to receive all fragments of a particular IPSec or IP
packet for reassembly.
              
The tmnxIpTunnelReassembly value set to zero indicates that reassembly
is disabled.
              
The default tmnxIpTunnelReassembly value indicates that this value
will be derived from the value of
TIMETRA-CHASSIS-MIB::tmnxIPsecIsaGrpTunnelReassembly object.
              
An 'inconsistentValue' error is returned if the value is not a
multiple of 100 milliseconds.

Context

MIB
TIMETRA-SAP-MIB
OID
.1.3.6.1.4.1.6527.3.1.2.4.3.142.1.19
Type
column
Access
readwrite
Status
current
Units
milliseconds
Parent
tmnxIpTunnelEntry
Table
tmnxIpTunnelTable
Siblings
34

Syntax

milliseconds Integer32

Values & Constraints

Object Constraints
range: -1-5000

Related Objects

Sibling Objects