tmnxRadSrvPlcyAcctStopMaxItvl
TIMETRA-RADIUS-MIB ·
.1.3.6.1.4.1.6527.3.1.2.79.1.2.2.1.116
Object
column r/w
secondsUnsigned32
The value of tmnxRadSrvPlcyAcctStopMaxItvl specifies the maximum
interval (in seconds) between retries to send the RADIUS accounting
stop message.
The value '0' specifies that no retries are performed.
The value specified must be bigger then or equal to the value
specified for the object tmnxRadSrvPlcyAcctStopMinItvl.
If a value '0' is specified for any of the objects
tmnxRadSrvPlcyAcctStopMinItvl, tmnxRadSrvPlcyAcctStopMaxItvl, or
tmnxRadSrvPlcyAcctStoplifetim, then all 3 objects will be set to '0'
by the system.
Context
- MIB
- TIMETRA-RADIUS-MIB
- OID
.1.3.6.1.4.1.6527.3.1.2.79.1.2.2.1.116- Type
- column
- Access
- readwrite
- Status
- current
- Units
- seconds
- Parent
- tmnxRadSrvPlcyEntry
- Groups
- 1
Net-SNMP examples
How SNMP and these commands workWalk the column to discover its indexed instances, or supply every index to read one instance.
Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'TIMETRA-RADIUS-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'TIMETRA-RADIUS-MIB::tmnxRadSrvPlcyAcctStopMaxItvl'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'TIMETRA-RADIUS-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'TIMETRA-RADIUS-MIB::tmnxRadSrvPlcyAcctStopMaxItvl.<tmnxRadSrvPlcyName>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'TIMETRA-RADIUS-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'TIMETRA-RADIUS-MIB::tmnxRadSrvPlcyAcctStopMaxItvl'
Syntax
secondsUnsigned32
Values & Constraints
Object Constraints
range: 0-3600
Conformance
Member of