tmnxRadSrvPlcyAcctInterimMinItvl
TIMETRA-RADIUS-MIB ·
.1.3.6.1.4.1.6527.3.1.2.79.1.2.2.1.112
Object
column
r/w
seconds Unsigned32
The value of tmnxRadSrvPlcyAcctInterimMinItvl specifies the minimum
interval (in seconds) between retries to send the RADIUS accounting
interim update message.
The value '0' specifies that no retries are performed.
The value specified must be less then or equal to the value specified
for the object tmnxRadSrvPlcyAcctInterimMaxItvl.
If a value '0' is specified for any of the objects
tmnxRadSrvPlcyAcctInterimMinItvl, tmnxRadSrvPlcyAcctInterimMaxItvl, or
tmnxRadSrvPlcyAcctInterimlifetim, then all 3 objects will be set to
'0' by the system.
Context
- MIB
- TIMETRA-RADIUS-MIB
- OID
.1.3.6.1.4.1.6527.3.1.2.79.1.2.2.1.112- Type
- column
- Access
- readwrite
- Status
- current
- Units
- seconds
- Parent
- tmnxRadSrvPlcyEntry
Syntax
seconds Unsigned32
Values & Constraints
Object Constraints
range: 0-3600