tmnxRadScriptPlcyOnFail
TIMETRA-RADIUS-MIB ·
.1.3.6.1.4.1.6527.3.1.2.79.1.3.1.1.5
Object
column r/w
Enumeration
The value of tmnxRadScriptPlcyOnFail specifies the action taken when
Python fails to modify the RADIUS message.
When the value is 'passthrough' the packet will be sent out without
any modifications.
When the value is 'drop' the packet will be dropped.
Context
- MIB
- TIMETRA-RADIUS-MIB
- OID
.1.3.6.1.4.1.6527.3.1.2.79.1.3.1.1.5- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- tmnxRadScriptPlcyEntry
- Groups
- 1
Net-SNMP examples
How SNMP and these commands workWalk the column to discover its indexed instances, or supply every index to read one instance.
Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'TIMETRA-RADIUS-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'TIMETRA-RADIUS-MIB::tmnxRadScriptPlcyOnFail'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'TIMETRA-RADIUS-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'TIMETRA-RADIUS-MIB::tmnxRadScriptPlcyOnFail.<tmnxRadScriptPlcyName>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'TIMETRA-RADIUS-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'TIMETRA-RADIUS-MIB::tmnxRadScriptPlcyOnFail'
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | passthrough |
2 | drop |
Conformance
Member of