tmnxOspfReferenceBandwidthU64Lo
TIMETRA-OSPF-NG-MIB ·
.1.3.6.1.4.1.6527.3.1.2.36.39.1.46
Object
The value of the object tmnxOspfReferenceBandwidthU64Lo specifies the
lower 32 bit of the reference bandwidth that needs to be used to
calculate the cost metric.
This value should always be set along with
tmnxOspfReferenceBandwidthU64Hi, otherwise an 'inconsistentValue'
error is returned.
The cost metric is calculated by dividing the value of the reference
bandwidth by the bandwidth of the interface.
The default value of 100,000,000 Kbps or 100 Gps provides a
10-Mbs link with a cost of 10000, a 100-Mbs link with a cost of
1000, a 1-Gbs link with a cost of 100 and
10-Gbs link with a cost of 10. To override this default cost
on a particular interface, set tmnxOspfIfCfgMetric for that
interface.