tmnxOspfIfMD5KeyStopTime

TIMETRA-OSPF-NG-MIB · .1.3.6.1.4.1.6527.3.1.2.36.22.1.5

Object

column obsolete r/w SNMPv2-TCDateAndTime
The value of tmnxOspfIfMD5KeyStopTime specifies the date and time when
this MD5 authentication key becomes invalid for use. If no date and
time is set, represented by a DateAndTime string with 0 length, the
key is valid indefinitely.

Context

MIB
TIMETRA-OSPF-NG-MIB
OID
.1.3.6.1.4.1.6527.3.1.2.36.22.1.5
Type
column
Access
readwrite
Status
obsolete
Parent
tmnxOspfIfMD5KeyEntry
Groups
2

Walk the column to discover its indexed instances, or supply every index to read one instance.

Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'TIMETRA-OSPF-NG-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'TIMETRA-OSPF-NG-MIB::tmnxOspfIfMD5KeyStopTime'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'TIMETRA-OSPF-NG-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'TIMETRA-OSPF-NG-MIB::tmnxOspfIfMD5KeyStopTime.<vRtrID>.<tmnxOspfVersion>.<tmnxOspfInstance>.<tmnxOspfIfIndex>.<tmnxOspfIfInstId>.<tmnxOspfIfMD5KeyIndex>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'TIMETRA-OSPF-NG-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'TIMETRA-OSPF-NG-MIB::tmnxOspfIfMD5KeyStopTime'

Syntax

Source
SNMPv2-TCDateAndTime
Base type
OctetString
Display format
2d-1d-1d,1d:1d:1d.1d,1a1d:1d
Type Description
A date-time specification.
          
field  octets  contents                  range
-----  ------  --------                  -----
  1      1-2   year*                     0..65536
  2       3    month                     1..12
  3       4    day                       1..31
  4       5    hour                      0..23
  5       6    minutes                   0..59
  6       7    seconds                   0..60
               (use 60 for leap-second)
  7       8    deci-seconds              0..9
  8       9    direction from UTC        '+' / '-'
  9      10    hours from UTC*           0..13
 10      11    minutes from UTC          0..59
          
* Notes:
- the value of year is in network-byte order
- daylight saving time in New Zealand is +13
          
For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be
displayed as:
          
                 1992-5-26,13:30:15.0,-4:0
          
Note that if only local time is known, then timezone
information (fields 8-10) is not present.

Values & Constraints

Type Constraints
range: 8 range: 11