tmnxOesDbSyncFailure
TIMETRA-OES-MIB ·
.1.3.6.1.4.1.6527.3.1.3.98.0.3
Object
notification
The active Equipment Controller is unable to synchronize its database
with the inactive Equipment Controller.
[CAUSE] The tmnxOesDbSyncFailure notification may be raised under the
following conditions:
1) An incorrectly seated Equipment Controller;
2) The software versions on the active and inactive Equipment
Controllers are not compatible;
3) A hardware problem with one or both controllers.
[EFFECT] The OES does not have redundancy protection between the two
Equipment Controller cards.
[RECOVERY] Proceed as follows to clear the Database Synchronization
Failed alarm:
1) Remove the Equipment Controller with the condition and examine
the connector on the back of the card for damage, including bent
or broken pins;
2) Examine the connector on the backplane for damage. If there is
damage to the backplane of the shelf, contact your service
representative;
3) Re-insert the Equipment Controller into its original slot and
allow the card to initialize;
4) Repeat Step 2) through Step 4) for the second Equipment
Controller;
5) Replace the Equipment Controller with the alarm condition with a
new unit. If the condition is not cleared, replace the second
Equipment Controller with a new unit.
Follow the return and repair process to return the faulty card to
an authorized repair center for replacement.
Context
- MIB
- TIMETRA-OES-MIB
- OID
.1.3.6.1.4.1.6527.3.1.3.98.0.3- Type
- notification
- Status
- current
- Parent
- tmnxOesNotifications
- Groups
- 1
Net-SNMP examples
How SNMP and these commands workNotifications are emitted by an agent; they cannot be read with snmpget or walked.
Inspect the notification definition
/usr/bin/snmptranslate -Pud -Ir -Td -m 'TIMETRA-OES-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'TIMETRA-OES-MIB::tmnxOesDbSyncFailure'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'TIMETRA-OES-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'TIMETRA-OES-MIB::tmnxOesDbSyncFailure'
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Conformance
Member of