tmnxOesRedundancyFail
TIMETRA-OES-HARDWARE-MIB ·
.1.3.6.1.4.1.6527.3.1.3.99.1.30
Object
notification
[CAUSE] The tmnxOesRedundancyFail notification is generated when the
inactive equipment controller card in the OES is not providing
redundancy protection. In some cases this is a transitory alarm that
occurs as redundant Equipment Controllers discover one another and
synchronize. Typical causes for the persistence of this alarm are:
1) Irreconcilable database schemas.
2) Inability to support system timing.
3) System timing is compromised. The inactive controller system
timing module is not reporting the same status as the active
controller or is reporting an error that the active controller
does not have.
4) Subshelf link missing.
Reasons that are generally transitory are:
1) Database not yet fully synchronized.
2) Software loads are not yet synchronized.
Some or all of these may apply when the alarm is raised.
[EFFECT] The OES is not protected against failure of the active
Equipment Controller.
[RECOVERY] Check for the Redundancy demerit in the detailed information
of the chassis indicated.
Context
- MIB
- TIMETRA-OES-HARDWARE-MIB
- OID
.1.3.6.1.4.1.6527.3.1.3.99.1.30- Type
- notification
- Status
- current
- Parent
- tmnxOesHwNotifications
- Groups
- 1
Net-SNMP examples
How SNMP and these commands workNotifications are emitted by an agent; they cannot be read with snmpget or walked.
Inspect the notification definition
/usr/bin/snmptranslate -Pud -Ir -Td -m 'TIMETRA-OES-HARDWARE-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'TIMETRA-OES-HARDWARE-MIB::tmnxOesRedundancyFail'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'TIMETRA-OES-HARDWARE-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'TIMETRA-OES-HARDWARE-MIB::tmnxOesRedundancyFail'
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Conformance
Member of