tmnxOesRedundancyFail

TIMETRA-OES-HARDWARE-MIB · .1.3.6.1.4.1.6527.3.1.3.99.1.30

Object

notification
[CAUSE] The tmnxOesRedundancyFail notification is generated when the 
inactive equipment controller card in the OES is not providing 
redundancy protection. In some cases this is a transitory alarm that 
occurs as redundant Equipment Controllers discover one another and 
synchronize. Typical causes for the persistence of this alarm are:
  1) Irreconcilable database schemas.
  2) Inability to support system timing.
  3) System timing is compromised. The inactive controller system 
     timing module is not reporting the same status as the active 
     controller or is reporting an error that the active controller 
     does not have.
  4) Subshelf link missing.
Reasons that are generally transitory are:
  1) Database not yet fully synchronized.
  2) Software loads are not yet synchronized.
Some or all of these may apply when the alarm is raised.
          
[EFFECT] The OES is not protected against failure of the active 
Equipment Controller.
          
[RECOVERY] Check for the Redundancy demerit in the detailed information
of the chassis indicated.

Context

MIB
TIMETRA-OES-HARDWARE-MIB
OID
.1.3.6.1.4.1.6527.3.1.3.99.1.30
Type
notification
Status
current
Parent
tmnxOesHwNotifications
Groups
1

Notifications are emitted by an agent; they cannot be read with snmpget or walked.

Inspect the notification definition
/usr/bin/snmptranslate -Pud -Ir -Td -m 'TIMETRA-OES-HARDWARE-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'TIMETRA-OES-HARDWARE-MIB::tmnxOesRedundancyFail'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'TIMETRA-OES-HARDWARE-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'TIMETRA-OES-HARDWARE-MIB::tmnxOesRedundancyFail'

Syntax

No syntax metadata recorded.

Values & Constraints

No enumerated values or constraints recorded.

Conformance