tmnxOamTwlSrcUdpPoolsPoolType

TIMETRA-OAM-TEST-MIB · .1.3.6.1.4.1.6527.3.1.2.11.9.5.1.2

Object

column r/w Enumeration
The value of tmnxOamTwlSrcUdpPoolsPoolType specifies the application
that can configure tests or sessions using the corresponding source
UDP port.
              
Values:
    oamPm(1)
        An OAM Performance Monitoring session, as configured using
        TIMETRA-OAM-PM-MIB::tmnxOamPmCfgSessIpSrcUdpPort.
    linkMeasurement(2)
        An OAM link measurement test, as configured using
        tmnxOamLnkMeasTmplCtlSrcUdpPort.
        OR
        An OAM LAG Measurement test, as configured using
        tmnxOamLagMeasTmplCtlSrcUdpPort.
              
Only source UDP ports assigned to the application can make use of this
source UDP port. A source UDP port cannot be allocated to a different
application if it is part of a configured test or session, regardless
of that test's or session's administrative or operational state.

Context

MIB
TIMETRA-OAM-TEST-MIB
OID
.1.3.6.1.4.1.6527.3.1.2.11.9.5.1.2
Type
column
Access
readwrite
Status
current
Default
oamPm
Parent
tmnxOamTwlSrcUdpPoolsEntry
Groups
1

Walk the column to discover its indexed instances, or supply every index to read one instance.

Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'TIMETRA-OAM-TEST-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'TIMETRA-OAM-TEST-MIB::tmnxOamTwlSrcUdpPoolsPoolType'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'TIMETRA-OAM-TEST-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'TIMETRA-OAM-TEST-MIB::tmnxOamTwlSrcUdpPoolsPoolType.<tmnxOamTwlSrcUdpPoolsPort>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'TIMETRA-OAM-TEST-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'TIMETRA-OAM-TEST-MIB::tmnxOamTwlSrcUdpPoolsPoolType'

Syntax

Enumeration

Values & Constraints

Enumerated Values
1oamPm
2linkMeasurement

Conformance