tmnxOamPingCtlMtuStartSize
TIMETRA-OAM-TEST-MIB ·
.1.3.6.1.4.1.6527.3.1.2.11.1.3.1.12
Object
column
r/w
Octets Unsigned32
The value of tmnxOamPingCtlMtuStartSize specifies the size of the
first OAM Echo message sent as part of an 'mtuPing' test.
Setting this object to a non-zero value is a prerequisite for starting
an 'mtuPing' test. Its value must be less than or equal to the value
of tmnxOamPingCtlMtuEndSize.
An attempt to set this object from a non-zero value to zero will fail
with a wrongValue error.
Changing the message size is a method of checking the ability of an
SDP to support a particular path-mtu value. The size of the message
does not include the SDP encapsulation, VC-Label (if applied) or any
DLC headers or trailers.
Context
- MIB
- TIMETRA-OAM-TEST-MIB
- OID
.1.3.6.1.4.1.6527.3.1.2.11.1.3.1.12- Type
- column
- Access
- readwrite
- Status
- current
- Units
- Octets
- Parent
- tmnxOamPingCtlEntry
Syntax
Octets Unsigned32
Values & Constraints
Object Constraints
range: 0-0
range: 40-9786