tmnxOamEthCfmPingCtlSrcMdIndex

TIMETRA-OAM-TEST-MIB · .1.3.6.1.4.1.6527.3.1.2.11.1.23.1.2

Object

The value of tmnxOamEthCfmPingCtlSrcMdIndex specifies the source CFM
Maintenance Domain (MD) index for the test.
              
The source domain can be specified using tmnxOamEthCfmPingCtlSrcMdName
or tmnxOamEthCfmPingCtlSrcMdIndex (not both).
tmnxOamEthCfmPingCtlSrcMdName is the preferred object for specifying
the source domain.
              
One of tmnxOamEthCfmPingCtlSrcMdName and
tmnxOamEthCfmPingCtlSrcMdIndex should be assigned a non-default value.
Otherwise, an attempt to start the test will fail.
              
If specified, tmnxOamEthCfmPingCtlSrcMdIndex should match a domain
created using TIMETRA-IEEE8021-CFM-MIB::tmnxDot1agCfmMdMgmtRowStatus.
Otherwise, the test will fail.
              
An attempt to change TIMETRA-SYSTEM-MIB::tmnxSysMgmtIfWriteMode.0 away
from 'classic(1)' is blocked if any tmnxOamEthCfmPingCtlSrcMdIndex has
a non-default value.
              
Zero indicates a value has not been configured.

Context

MIB
TIMETRA-OAM-TEST-MIB
OID
.1.3.6.1.4.1.6527.3.1.2.11.1.23.1.2
Type
column
Access
readwrite
Status
current
Default
0
Parent
tmnxOamEthCfmPingCtlEntry
Groups
1

Walk the column to discover its indexed instances, or supply every index to read one instance.

Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'TIMETRA-OAM-TEST-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'TIMETRA-OAM-TEST-MIB::tmnxOamEthCfmPingCtlSrcMdIndex'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'TIMETRA-OAM-TEST-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'TIMETRA-OAM-TEST-MIB::tmnxOamEthCfmPingCtlSrcMdIndex.<tmnxOamPingCtlOwnerIndex>.<tmnxOamPingCtlTestIndex>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'TIMETRA-OAM-TEST-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'TIMETRA-OAM-TEST-MIB::tmnxOamEthCfmPingCtlSrcMdIndex'

Syntax

Source
SNMPv2-SMIUnsigned32
Base type
Unsigned32

Values & Constraints

Type Constraints
range: 0..4294967295

Conformance